Xact to M1.5i conversion documentation: preload_opt and mrinput attribute


Record #6254

Problem Title:
Xact to M1.5i conversion documentation: preload_opt and mrinput attribute


Problem Description:
Urgency: standard

General Description:

Application note ftp://ftp.xilinx.com/pub/documentation/M1/convergd_m1_5.pdfInternet Link
talks about the conversion of designs from Xact to M1.x. On page 20, there is a chart to compare the attributes from Xact and how to convert it into M1.x.
There is a mention of the PRELOAD_OPT and the MRINPUT attributes which are not
available as attributes for M1.x but can be found in the gui.



Solution 1:

Solution:

The MRINPUT and PRELOAD_OPT are only 7000 series attributes. These attributes
are not supported on the 9500 family in M1.x.





End of Record #6254 - Last Modified: 06/03/99 12:54