Answers Database


SYNPLIFY: The xc_loc attribute does not correctly write the LOC property to the EDIF for Virtex


Record #6255

Product Family: Software

Product Line: Synplicity

Product Part: Synplify

Product Version: 5.0

Problem Title:
SYNPLIFY: The xc_loc attribute does not correctly write the LOC property to the EDIF for Virtex



Problem Description:
Urgency:Standard

General Description:
The xc_loc attribute does not correctly write the LOC
property to the EDIF for Virtex


Solution 1:

This is fixed in 5.1.4



Solution 2:

This is broken again in 5.1.5a. The fix is to use our constraints edittor and manually add the pin lock constraint or manually edit the ucf and loc the constraint there. Synplicity is aware of this
  issue and hopes to repair this with the next release.




End of Record #6255 - Last Modified: 09/16/99 12:58