Answers Database
ngdbuild: ngdbuild does not error with conflicting LOCs
Record #6301
Product Family: Software
Product Line: FPGA Implementation
Product Part: ngdbuild
Product Version: 1.5is2
Problem Title:
ngdbuild: ngdbuild does not error with conflicting LOCs
Problem Description:
Urgency: standard
Problem Description:
When specifying same property(attribute) of different values onto
the same PADthrough different design elements, such as PAD or
PAD NET ngdbuild doesn't give errors on duplicated properties(attributes).
Instead it chooses the properties(attributes) that are applied on the net.
Solution 1:
The above situation only happens when using Foundation or Viewlogic
schematic tools. These properties or attributes include:
LOC
TNM
IO_STANDARD
Drive
Make sure that only one valid value is used on either the PAD or PAD NET.
End of Record #6301 - Last Modified: 04/27/99 16:48 |