Answers Database
1.5i, 2.1i 4KX* PAR - Pad report contains TDO as a reserved pin even when not using boundary scan
Record #6335
Problem Title:
1.5i, 2.1i 4KX* PAR - Pad report contains TDO as a reserved pin even when not using boundary
scan
Problem Description:
Urgency: Standard
General Description:
A design targetting a 4062XL-CB228 writes out a PAD report that contains TDO as a reserved pin even
if boundary scan is not being used.
Solution 1:
This is an error in the .pad report file which will be fixed in the first major
release (as yet un-named) following version 2.1i..
End of Record #6335 - Last Modified: 06/26/99 14:20 |