Answers Database


ngdbuild Virtex designs: ERROR:basnu:118 - logical net "xxxx" has both a pullup and a pulldown.


Record #6406

Product Family: Software

Product Line: FPGA Implementation

Product Part: ngdbuild

Product Version: 2.1i

Problem Title:
ngdbuild Virtex designs: ERROR:basnu:118 - logical net "xxxx" has both a pullup and a pulldown.



Problem Description:
Urgency: Standard

Problem Description:

ngdbuild currently adds a pullup to a BUFT net. If a user has a pulldown
connected to this net, ngdbuild will issue the following error:

ERROR:basnu:118 - logical net "xxxx" has both a pullup and a pulldown.


Solution 1:

For Virtex designs, pullups and pulldowns are mainly used in the IO blocks.
Pulldowns can't be connected to the output of the internal BUFTs. To avoid
the error, pulldowns have to be removed from the design.




End of Record #6406 - Last Modified: 05/11/99 10:41

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!