ngdbuild: BUFE or BUFT cannot drive an OPAD directly for Virtex. ERROR xvkpu - The symbol page1$4p/i5 failed to join a regular I/O component as required. Buffer is not an I/O buffer.
Record #6435
Product Family: Software
Product Line: FPGA Implementation
Product Part: ngdbuild
Product Version: 2.1i
Problem Title:
ngdbuild: BUFE or BUFT cannot drive an OPAD directly for Virtex. ERROR xvkpu - The symbol
page1$4p/i5 failed to join a regular I/O component as required. Buffer is not an I/O buffer.
Problem Description:
Urgency: Standard
Problem Description:
ngdbuild will issue the following error is a BUFE or BUFT output drives the OPAD directly:
ERROR:xvkpu - The symbol page1$4p/i5 failed to join a regular I/O component as
required. Buffer is not an I/O buffer.
Solution 1:
Using the output of BUFT or BUFE to drive OPAD is actually an illegal connection. Users
should use OBUFT or OBUFE components instead.
End of Record #6435 - Last Modified: 05/10/99 11:44 |