Answers Database
2.1i Timing Analyzer: Does not accept decimal or negative values for temprature in prorating options
Record #6566
Product Family: Software
Product Line: FPGA Implementation
Product Part: Timing Analyzer
Product Version: 2.1i
Problem Title:
2.1i Timing Analyzer: Does not accept decimal or negative values for temprature in prorating
options
Problem Description:
Urgency: Standard
General Description:
For decimals, the temperature prorating values are incorrectly
coverted. For example, 42.5 becomes 425.00.
Additionally, negative values cannot be specified in the prorating
window, even though they are listed in the window as a valid
input.
Solution 1:
Decimal values are currently NOT supported within temperature
prorating. Additionally, negative values currently cannot be input
through the timing analyzer GUI. However, this can be added
to the PCF file.
These issue will be address in a future software release.
End of Record #6566 - Last Modified: 01/14/00 11:01 |