Answers Database


1.5i SP2 PAR - Fatal Error bascmpindly .c 256:1.18 config string parse error -- primitive ocemuh is not in clkiob


Record #6657

Product Family: Software

Product Line: FPGA Implementation

Product Part: par

Product Version: 1.5is2

Problem Title:
1.5i SP2 PAR - Fatal Error bascmpindly .c 256:1.18 config string parse error -- primitive
ocemuh is not in clkiob



Problem Description:
PAR aborts with error:

Fatal Error: bascm bascmpindly.c:256:1.18 Config string parse error
primitive ocemuh is not in clkiob. Process will terminate. Please call
Xilinx Technical Support.

This is a problem with the syntax of the EDN file -- a parse error.


Solution 1:

There are a few permutations of this particular error 256:1.18, and
some are caused by a bad install of the Xilinx tools. A reinstall will
correct the problem.




End of Record #6657 - Last Modified: 06/08/99 15:07