Answers Database
Mentor: I can not check nor convert my old 4K (4000 non-E) schematic design to 4KE or 4KX using A1.5 or later Xilinx software
Record #6897
Product Family: Software // Error: Could not determine current version of and2/part for instance I$1 // Error: Could not determine current version of bufg/part for instance I$2 And running Convert Design I am getting messages similiar to the following in the transcript window: // Error: Library -->$LCA/xc4000/ does not exist . (from: Uims/base_toolkit/ui_session_tk 01 OR in the pld_da window I see: Error: Library -->$LCA/xc4000/ does not exist Solution 1: This is due to the fact that in the A1.5 and later software the XC4000 library was removed due to library install size reasons. Also since the silicon is no longer available the library was removed to deter any NEW designs into the XC4000 (non-E) devices. In order to run Convert Design you must have the XC4000 library in the $LCA ($XILINX/mentor/data) area. This library can be downloaded from the Xilinx ftp site: (Xilinx File ftp://ftp.xilinx.com/pub/swhelp/mentor/xc4000.tar.Z You must have write privelages into the $LCA directory in order to copy these library files. For more information on running Convert Design please see (Xilinx Solution 798) End of Record #6897 - Last Modified: 06/28/99 10:49 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |