2.1i Virtex PAR - Using the -k switch on Virtex designs may cause a Segmentation Fault/ Access Violation in PAR.
Record #7052
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 2.1i
Problem Title:
2.1i Virtex PAR - Using the -k switch on Virtex designs may cause a Segmentation Fault/
Access Violation in PAR.
Problem Description:
Urgency: Standard
Problem Description:
A case has been seen where PAR crashes on a Virtex design, only if Map
is run using the -k option. The crash has been determined to be related to
timing analysis and is still under investigation.
Solution 1:
This problem is fixed in the latest 2.1i Service Pack available at:
http://support.xilinx.com/support/techsup/sw_updates/
End of Record #7052 - Last Modified: 10/18/99 10:30 |