Answers Database
NGDBUILD 2.1i: ERROR:basla:20 Launcher: virtex is not a valid PM name (ERROR basnb:64 could not initialize netlister)
Record #7076
Product Family: Software
Product Line: FPGA Implementation
Product Part: ngdbuild
Product Version: 2.1i
Problem Title:
NGDBUILD 2.1i: ERROR:basla:20 Launcher: virtex is not a valid PM name (ERROR basnb:64 could
not initialize netlister)
Problem Description:
Urgency: Standard
General Description: When trying to run ngdbuild on a Virtex design, the following
errors occur:
ERROR:basla:20 - Launcher: virtex is not a valid PM name.
ERROR:basnb:64 - Could not initialize Netlister Launcher due to above
errors.
Solution 1:
These errors occur when an xnf is passed to ngdbuild for a Virtex design. All
Virtex design netlists must be in the EDIF format. Resynthesis or regeneration
of the netlists will be necessary.
End of Record #7076 - Last Modified: 08/05/99 18:24 |