Answers Database
2.1i 4KX* PAR - Dr Watson during routing. Access violation (0xc0000005), Address: 0x0024b0b1
Record #7249
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 2.1i
Problem Title:
2.1i 4KX* PAR - Dr Watson during routing. Access violation (0xc0000005), Address:
0x0024b0b1
Problem Description:
Urgency: Standard
General Description:
Exceptopn: access violation (0xc0000005), Address: 0x0024b0b1
This crash was due to PAR failing to handle a unusual case where a net
has no pins. This was occuring due to the use of a KEEP property on a
net that was connected to unused logic which was trimmed.
Solution 1:
This problem is fixed in the latest 2.1i Service Pack available at:
http://support.xilinx.com/support/techsup/sw_updates/
End of Record #7249 - Last Modified: 10/18/99 10:15 |