Answers Database
2.1i SpartanXL PAR - PAR fails to produce consistent results when running a cost table twice.
Record #7335
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 2.1i
Problem Title:
2.1i SpartanXL PAR - PAR fails to produce consistent results when running a cost table
twice.
Problem Description:
Design scores vary between designs run using Multi-Pass PAR and single pass PAR.
Solution 1:
This problem is fixed in the latest 2.1i Service Pack available at:
http://support.xilinx.com/support/techsup/sw_updates/
End of Record #7335 - Last Modified: 10/18/99 10:21 |