2.1i SpartanXL PAR - FATAL_ERROR:Route:basrtsanity.c:241:1.1.2.2 -Process will terminate.


Record #7342

Product Family: Software

Product Line: FPGA Implementation

Product Part: par

Product Version: 2.1i

Problem Title:

2.1i SpartanXL PAR - FATAL_ERROR:Route:basrtsanity.c:241:1.1.2.2 -Process will terminate.


Problem Description:
Design targeting an S40XL with PCI design fails with:

   FATAL_ERROR:Route:basrtsanity.c:241:1.1.2.2 -Process will terminate.

  This is caused by the fact that the PCI design is using TBUFs as route thrus and
the placer is not dealing with them correctly. A work around for this problem is to prohibit the tbufs that can't be used directly.


Solution 1:

This problem is fixed in the latest 2.1i Service Pack available at:
http://support.xilinx.com/support/techsup/sw_updates/




End of Record #7342 - Last Modified: 10/18/99 10:24