Answers Database


2.1i V150-FG456 - PAD report does not match datasheets


Record #7489

Product Family: Software

Product Line: Merged Core

Product Part: packages

Problem Title:

2.1i V150-FG456 - PAD report does not match datasheets


Problem Description:
Urgency: standard


Using 2.1i-sp1 it appears that the PAD report for the V150-FG456 is not complete. The pad report does not properly report all No Connects in the PAD report.


Solution 1:

A fix is scheduled for the 2.1i SP3 update which is due to become available in
early November.




End of Record #7489 - Last Modified: 09/10/99 10:53

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!