Answers Database


XPLA PC-ISP Programmer: Debug tips on custom built download cables


Record #7570

Product Family: Software

Product Line: CoolRunner

Product Part: XPLA ISP

Problem Title:

XPLA PC-ISP Programmer:	Debug tips on custom built download cables 


Problem Description:
Urgency: Hot

General Description: I have a custom built download cable that does
not seem to work, how do I debug this?


Solution 1:

    1.Verify that if the cable is passive, that 100 Ohm series termination
    resistors are in place at the DB25 end of the cable.
    2.Verify that the parallel port driver is mapped correctly by reading
    item number 7 at (Xilinx Solution 7569).
    3.Verify that all signals are interleaved with a ground signal.
    4.Check correct pin out. Refer to the JTAG header pinout item
    number 8 at (Xilinx Solution 7569) and the DB25 pinout item
    number 13 at (Xilinx Solution 7569).




End of Record #7570 - Last Modified: 10/11/99 16:49

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!