Answers Database
2.1i COREGEN, C_IP2: Incorrect latency values reported by Virtex Parallel Multiplier GUI
Record #7572
Product Family: Software
Product Line: LogiCore
Product Part: Coregen IP Modules
Problem Title:
2.1i COREGEN, C_IP2: Incorrect latency values reported by Virtex Parallel Multiplier GUI
Problem Description:
Urgency: standard
General Description:
The latency values reported in the Virtex Multiplier GUI do not match the
values documented in the datasheet for this module.
Solution 1:
The values documented in the datasheet are the correct values.
End of Record #7572 - Last Modified: 11/08/99 11:23 |