Answers Database


Foundation 2.1i simulation: Error- Bus Conflicts during Foundations simulation, while simulating multiplexer with tri-stated buffers


Record #7680

Problem Title:
Foundation 2.1i simulation: Error- Bus Conflicts during Foundations simulation, while simulating multiplexer with tri-stated buffers



Problem Description:
Urgency: Standard

General Description: When doing a functional simulation in
Foundation with a design containing multiplexor with using
tri-stated buffers or logiblox generated multiplexor, a window
pops up during simulation titled 'Bus Conflicts'.


Solution 1:

This is currently a known issue with the Foundation logic
simulator and the warning message that is generated can be
safely ignored.

When a Logiblox MUX is generated with more than four inputs,
the default is to implement the MUX using tri-state buffers.
The simulator has problems interpreting the buffers and
generates the Bus Conflicts error.

The currently work-around is
Ignore the warnings that pop up. Click on Cancel.





End of Record #7680 - Last Modified: 09/28/99 14:37