Answers Database


F2.1i Schematic Editor: How to add PWR and GND symbols now that the "Power Symbol" button has gone.


Record #7699

Product Family: Software

Product Line: Aldec

Product Part: Foundation Schematic Capture

Product Version: 2.1i

Problem Title:
F2.1i Schematic Editor: How to add PWR and GND symbols now that the "Power Symbol" button has gone.



Problem Description:
Urgency: Standard

General Description: In F1.5i and previous versions, there used to
be a "Power Symbol" button on the toolbar going down the left
hand side of the Schematic Capture window.

In 2.1i, this button has disappeared, so how do I add PWR and
GND to my design?



Solution 1:

The way to add power symbols to a Foundation schematic design,
is to use the "Symbols Toolbox" and select the components "VCC"
and "GND".

These components have always existed in the libraries and in actual
fact are the ones which should always have been used. The reason
for this is that "VCC" and "GND" are components contained in the
XILINX Unified Libraries. The PWR and GND symbols were Aldec
symbols and as such, were not components contained in the XILINX
Unified Libraries.

Note: The help files still refer to PWR and GND symbols, despite the
"Power Symbol" button no longer being included in the software.
The pages of the Help files, should be ignored.




End of Record #7699 - Last Modified: 09/28/99 14:39

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!