Answers Database
XPLA Professional: How to enable/disable JTAG pins on ISP parts when using Schematic Capture?
Record #7774
Product Family: XCR500
Product Line: XCR5128
Product Part: XCR5128
Problem Title:
XPLA Professional: How to enable/disable JTAG pins on ISP parts when using Schematic
Capture?
Problem Description:
Urgency: Standard
General Description: There are two different ways to enable/disable
the JTAG pins on ISP parts when using Schematic Capture.
Solution 1:
Use the control files. In the "Properties" window you can right click on the Control file field and
select a control file *.ctl. This is a text file that contains special information that you specify
. This
is discussed in the XPLA Professional User's manual and is also discussed in the Answers/Solutions
database.
Solution 2:
In the "Properties" window from the main GUI, you can check
or clear the " Reserve ISP Pins" box. A check mark means
keep the pins as JTAG function. A clear box means to allow the JTAG
pins to be used as I/Os.
End of Record #7774 - Last Modified: 10/14/99 17:57 |