Answers Database


XPLA : Warning - wired or in net = <signalname>


Record #7778

Product Family: Software

Product Line: CoolRunner

Product Part: XPLA Schematic

Product Version: 3.30

Problem Title:
XPLA : Warning - wired or in net = <signalname>


Problem Description:
Urgency: Standard

General Description: This warning occurs when the user attempts to take two signals and tie them to gether. Even if the two signals are both tri-stated, this warning will occur. Two signals can not be tied together via tri-state internally because each macrocell has only one tri-state buffer which
  can either
go directly to an output pad or back to the interconnect.


Solution 1:

Instead of tri-stating the two signals, mux them together using the
tri-state select as the mux select.



Solution 2:

Send the two tri-stated signals to two separate output pads and then tie the two pins together exter nally.




End of Record #7778 - Last Modified: 10/14/99 17:58