Answers Database


2.1i PAR - S40XLPQ240-5 pad report does not match data book


Record #7788

Product Family: Software

Product Line: FPGA Implementation

Product Part: par

Product Version: 2.1i

Problem Title:

2.1i PAR - S40XLPQ240-5 pad report does not match data book


Problem Description:
Urgency: Standard

The Spartan 40XL pq240 pad report generated from the flow engine produces different data from the da ta book. The Data Book mentions certain gnd pins that are "no-connects" in the pad report (and vice
-versa). Several other inconsistencies exist in the pad report as well.


Solution 1:

The data book has the correct information. Using the pin descriptions from the data book will be co rrect.




End of Record #7788 - Last Modified: 10/04/99 07:49

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!