Answers Database
PAR 2.1is2 - par report does not give the correct Vcco value for LVDS IO
Record #8000
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 2.1i
Problem Title:
PAR 2.1is2 - par report does not give the correct Vcco value for LVDS IO
Problem Description:
URGENCY: standard
GENERAL DESCRIPTION:
The PAR report details the Select IO Utilization and Usage Summary in a bank summary. The
details for banks containing LVDS specify that Vcco is designated as NR (Not Required).
Solution 1:
The report should be disregarded. Vcco should be tied to 2.5V
This problem is scheduled to be fixed in the next (as yet unnamed)
release following version 2.1i. This release is currently scheduled
for March, 2000.
End of Record #8000 - Last Modified: 12/14/99 16:38 |