Answers Database
Mentor: Check Design gives Error: Out of date reference; Version 1 of symbol "gnd", or of symbol "vcc"
Record #8075
Problem Title: Error: Out of date reference; Version 1 of symbol "gnd" is not the most current (2) for instance: I$3 Error: Out of date reference; Version 1 of symbol "vcc" is not the most current (2) for instance: I$5 Solution 1: In the A1.5i library the vcc and gnd symbol pin names were vcc and gnd, but now in 2.1i the pin names have changed to P and G. So the schematic sheets that have any vcc or gnd components must be updated by doing the following from within pld_da: 1) Right-mouse-click in the pld_da session window. (The window behind the schematic if the schematic is opened.) You may have to resize the schematic window, or minimzie it. 2) Choose the Update Design option. 3) Either enter in the top level name in the "Enter Top level design name" dialogue box, or use the Navigator button to select it. 4) Click on the "OK" button to proceed with updating the design. 5) Check the design. It should now finish without errors. 6) Save the updated design. End of Record #8075 - Last Modified: 11/18/99 16:07 |