Answers Database


PAR2.1isp3: Par hangs after the message "Starting Initial Timing Analysis"


Record #8182

Product Family: Software

Product Line: FPGA Implementation

Product Part: par

Product Version: 2.1is3

Problem Title:
PAR2.1isp3: Par hangs after the message "Starting Initial Timing Analysis"


Problem Description:
Urgency: Standard

General Description:
PAR appears to be hung during timing analysis when a Timing Ignore (TIG) constraint is specified in the UCF file. PAR hangs after the message "Starting Initial Timing Analysis"

Removing the TIG constraint on one of the nets solved the problem..


Solution 1:

This problem will be fixed in the next major release (as yet unnamed) after 2.1i. It is currently sc heduled to become available on March 21, 2000.




End of Record #8182 - Last Modified: 12/10/99 10:32