Answers Database
Foundation 2.1i Schematic Editor: "Line 3; Wrong number of fields; BUS"
Record #8212
Product Family: Software
Product Line: Aldec
Product Part: Foundation Schematic Capture
Product Version: 2.1is3
Problem Title:
Foundation 2.1i Schematic Editor: "Line 3; Wrong number of fields; BUS"
Problem Description:
Urgency: Standard
General Description:
When updating a VHDL macro, the following message is encountered:
"Line: 3
Wrong number of fields
BUS"
Solution 1:
The source of this message is a bus that was declared in the entity port
list, but not used in the architecture body.
End of Record #8212 - Last Modified: 12/06/99 11:08 |