Answers Database
2.1i 9500/XL Hitop: ERROR:CPLDFitter - NGD2NDS failed. The NDS network is not created due to errors
Record #8519
Product Family: Software
Product Line: CPLD Implementation
Product Part: hitop
Product Version: 2.1i
Problem Title:
2.1i 9500/XL Hitop: ERROR:CPLDFitter - NGD2NDS failed. The NDS network is not created due to
errors
Problem Description:
Urgency: Standard
General Description:
At the beginning of executing the CPLD Fitter, the design errors with the
following error message:
ERROR:CPLDFitter - NGD2NDS failed. The NDS network is not created due to errors.
Fatal: NGD2NDS did not create a network.
This is only seen in the Flow engine log window, and is not in any report files.
The fitter report may give the error:
ERROR:nd200 - Design 'name' has no outputs.
Solution 1:
The reason for this error is that all logic was removed from the design. This is
usually due to having no input or output pad connections in the design.
End of Record #8519 - Last Modified: 02/01/00 09:38 |