Answers Database


2.1i Spartan-XL PAR - Placer fails to place TDO comp when Exact Guide is used.


Record #8545

Problem Title:

2.1i Spartan-XL PAR - Placer fails to place TDO comp when Exact Guide is used.


Problem Description:
Urgency: Standard

General Description:
A case has been seen where the placer failed to place the TDO comp when Exact Guide is used. It worked okay if guide was not used.



Solution 1:

Work around for guided PAR is to use a PCF constraint to LOC the TDO comp:

    COMP "TDO_O" LOCATE = SITE "TDO" LEVEL 0 ;

A CR is pending.




End of Record #8545 - Last Modified: 02/03/00 17:19