Answers Database
2.1i COREGEN: 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the pinout table
Record #8576
Product Family: Software
Product Line: Coregen
Product Part: Coregen datasheets
Problem Title:
2.1i COREGEN: 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the
pinout table
Problem Description:
Urgency: standard
General Description:
The 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the pinout table
on page 4.
Solution 1:
The description for the RESULT port should be corrected to refer
to XK_R and XK_I instead of YK_R and YK_I:
FFT result strobe (active high). This signal indicates that a new (I)FFT result
vector is available. It frames the XK_R and XK_I output buses.
End of Record #8576 - Last Modified: 02/09/00 12:00 |