Answers Database


2.1i COREGEN: 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the pinout table


Record #8576

Product Family: Software

Product Line: Coregen

Product Part: Coregen datasheets

Problem Title:

2.1i COREGEN: 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the pinout table



Problem Description:
Urgency: standard

General Description:
The 64 point FFT datasheet erroneously refers to YK_R and YK_I ports in the pinout table on page 4.



Solution 1:

    The description for the RESULT port should be corrected to refer
    to XK_R and XK_I instead of YK_R and YK_I:

    FFT result strobe (active high). This signal indicates that a new (I)FFT result
    vector is available. It frames the XK_R and XK_I output buses.




End of Record #8576 - Last Modified: 02/09/00 12:00