September 19, 2000
Subject: The VirtexTM family contains a design
process related marginality that may affect functionality of the distributed
(LUT-based) SelectRAM when configured in a 32x1 mode.
It is recommended that customers do not use these devices in this mode.
This marginality issue occurs when a customer write enables data into
the LUT. The write strobe signal that loads the data into the memory cells
is not wide enough to accommodate the full range of process variation across
the die. The device then fails since some of the data was not written to
the memory address location. The failure is seen as a random LUT failure
typically at a single location within the array.
This failure is not time dependent; therefore, all devices that have
shipped in fully functional systems are not expected to experience field
failures. It is recommended that customers do not re-configure these devices
with different patterns containing 32x1 distributed RAM once they have
been deployed in the field.
Products Affected: All Virtex production devices, all
SpartanTM-II engineering (ES) devices, and some Spartan-II (non-ES)
production devices are affected. This design marginality does not affect
any Virtex-E production devices. This design marginality does not affect
any designs configured in a 16x1 mode.
Change Description: The design process marginality was
identified in all Virtex products. It is recommended that customers planning
to use the 32x1 configuration in their design instead use two LUT's configured
as 16x1 within a slice which can be combined to create a 32x1 bit RAM.
Xilinx plans to implement a fix for this design process marginality.
Reason For Change: The fix widens the write strobe signal
to accommodate a larger variation of memory cells.
Key Dates: Xilinx will issue a PCN (Product Change Notification)
in November, 2000, which will have more detail on product traceability
and availability. Xilinx plans to ship product with the fixed material
in Q1 2001.
Note added on 1/31/2001 - PCN2001-05 has
been released to detail product traceability and availability.
Response: No response to this notification is required.
Requests for additional data or support should be made to your local Xilinx
FAE, or email pcn@xilinx.com. |