RFC 2955






Network Working Group                                         K. Rehbehn
Request for Comments: 2955                               Megisto Systems
Category: Standards Track                                    O. Nicklass
                                           RAD Data Communications, Ltd.
                                                            G. Mouradian
                                                               AT&T Labs
                                                            October 2000


                     Definitions of Managed Objects
                   for Monitoring and Controlling the
           Frame Relay/ATM PVC Service Interworking Function

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

   This memo defines a Management Information Base (MIB) to configure,
   monitor, and control a service interworking function (IWF) for
   Permanent Virtual Connections (PVC) between Frame Relay and
   Asynchronous Transfer Mode (ATM) technologies.

Table of Contents

   1. The SNMP Management Framework ...............................   2
   2. Conventions .................................................   3
   3. Overview ....................................................   3
   3.1 Frame Relay/ATM Service Interworking Background ............   4
   3.2 Structure of the MIB .......................................   4
   3.3 Relationship to Other MIBs .................................   5
   3.3.1 Frame Relay Service MIB ..................................   6
   3.3.2 Frame Relay DTE MIB ......................................   6
   3.3.3 ATM MIB ..................................................   6
   3.3.4 IF MIB ...................................................   7
   3.4 Point to Multipoint Considerations .........................   7
   3.5 Theory of Operation ........................................   7
   3.5.1 Creation Process .........................................   7
   3.5.2 Destruction Process ......................................  10



Rehbehn, et al.             Standards Track                     [Page 1]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   3.5.3 Modification Process .....................................  11
   4. Object Definitions ..........................................  11
   4.1 The FR/ATM PVC Service IWF Connection Group ................  13
   4.2 The FR/ATM PVC Service IWF Connection Descriptor Group .....  21
   5. Augmentation of ATM MIB VCL Endpoint Entry (atmVclEntry) ....  27
   6. Frame Relay/ATM PVC Service Interworking NOTIFICATION .......  29
   7. Conformance Information .....................................  29
   7.1 Compliance Statement For Equipment .........................  29
   7.2 Compliance Statement For Service (CNM Interface) ...........  30
   7.3 Units of Conformance .......................................  32
   7.3.1 Basic FR/ATM IWF PVC Connection Group ....................  32
   7.3.2 FR/ATM IWF PVC Connection Descriptor Group ...............  32
   7.3.3 ATM MIB VCL Endpoint Table Augmentation ..................  33
   7.3.4 Notification Group .......................................  33
   8. Acknowledgments .............................................  34
   9. References ..................................................  34
   10. Security Considerations ....................................  36
   11. Authors' Addresses .........................................  37
   12. Intellectual Property Rights ...............................  38
   13. Full Copyright Statement ...................................  39

1.  The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

   o  An overall architecture, described in RFC 2571 [1].

   o  Mechanisms for describing and naming objects and events for the
      purpose of management.  The first version of this Structure of
      Management Information (SMI) is called SMIv1 and described in STD
      16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4].  The
      second version, called SMIv2, is described in STD 58, RFC 2578
      [5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7].

   o  Message protocols for transferring management information.  The
      first version of the SNMP message protocol is called SNMPv1 and
      described in STD 15, RFC 1157 [8].  A second version of the SNMP
      message protocol, which is not an Internet standards track
      protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC
      1906 [10].  The third version of the message protocol is called
      SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574
      [12].








Rehbehn, et al.             Standards Track                     [Page 2]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   o  Protocol operations for accessing management information.  The
      first set of protocol operations and associated PDU formats is
      described in STD 15, RFC 1157 [8].  A second set of protocol
      operations and associated PDU formats is described in RFC 1905
      [13].

   o  A set of fundamental applications described in RFC 2573 [14] and
      the view-based access control mechanism described in RFC 2575
      [15].

   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [16].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64).  Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process.  However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.

2.  Conventions

   The keywords MUST, MUST NOT, REQUIRED, SHALL, SHALL NOT, SHOULD,
   SHOULD NOT, RECOMMENDED, NOT RECOMMENDED, MAY, and OPTIONAL, when
   they appear in this document, are to be interpreted as described in
   RFC 2119 [23].

3.  Overview

   This document defines a Management Information Base (MIB) for
   monitoring and controlling a service interworking function (IWF) for
   Permanent Virtual Connections (PVC) between Frame Relay and
   Asynchronous Transfer Mode (ATM) technologies.  The agreements on
   which this MIB is based were reached jointly by the Frame Relay Forum
   and the ATM Forum and are documented in the Frame Relay Forum
   Document FRF.8 [17].








Rehbehn, et al.             Standards Track                     [Page 3]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


3.1.  Frame Relay/ATM Service Interworking Background

   Frame relay to ATM interworking is a function that exchanges Protocol
   Data Units (PDU) between a frame relay service user and an ATM
   service user. Two types of interworking functions are specified for
   frame relay and ATM permanent virtual connection (PVC) service users:
   network interworking and service interworking.

   Network interworking provides PDU forwarding between frame relay
   service users inter-connected by an ATM service. Both endpoints are
   frame relay PVCs. Frame Relay to ATM PVC Network Interworking is
   defined in [20].

   Service interworking provides PDU forwarding so that the ATM service
   user performs no frame relaying service-specific functions and the
   frame relay service user performs no ATM service-specific functions.
   Optionally, the service IWF translates particular higher layer
   protocols to satisfy the requirements of end-systems.  Frame Relay to
   ATM PVC Service Interworking is defined in [17].

   This MIB describes management objects used to provision, monitor, and
   control a Frame Relay/ATM PVC Service IWF.

   FRF.8 [17] does not address point-to-multipoint applications of the
   IWF.  Implementations MAY provide support for point-to-multipoint
   capability using this MIB.

   Consult FRF.8 [17] for more details on the operation of a Frame
   Relay/ATM PVC Service IWF.

3.2.  Structure of the MIB

   The Frame Relay/ATM PVC Service IWF managed objects are organized as
   follows:

   (1) FR/ATM PVC Service IWF cross-connect table,

   (2) Connection description table, and

   (3) Notification object

   The IWF cross-connect table contains one or more rows for each
   inter-worked connection.  Each inter-worked connection is uniquely
   identified by the frAtmIwfConnIndex object. In the case of point-to-
   point, a single row is present.  In the case of point-to-multipoint,
   one row exists for each multipoint destination.  Index objects for
   the ATM port, VPI, VCI, frame relay port, and frame relay DLCI
   distinguish the constituent rows used in a point-to-multipoint case.



Rehbehn, et al.             Standards Track                     [Page 4]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   Each inter-worked connection has attributes governing behavior of the
   IWF.  These attributes describe how the IWF should transform a PDU
   during the forwarding process and provide rules for:

   (1) Mapping the ATM CLP bit to frame relay DE bit

   (2) Mapping the ATM congestion notification bit to frame relay
       congestion bits

   (3) Mapping higher protocol encapsulations between ATM and frame
       relay

   (4) Performing fragmentation and reassembly

   (5) Performing ARP translation between ATM and frame relay

   Typically, most connections share the same attributes.  The
   attributes are represented in this MIB by the connection description
   table.  Each row of the connection description table contains the
   attribute settings common to one or more inter-worked connections.
   One example would be full mapping and translation.  All cross-connect
   table entries that require full mapping and translation services set
   the frAtmIwfConnectionDescriptor object to the index value for the
   connection description table row that contains objects set to values
   that provide full mapping and translation services.

   A notification object provides cross-connect status change alerts.

3.3.  Relationship to Other MIBs

   The Frame Relay/ATM PVC Service IWF MIB describes the cross-
   connections between frame relay and ATM service users.  Each PVC
   endpoint is provisioned and managed with a technology-specific MIB as
   described below.

   Each technology-specific MIB has a table of PVC endpoints (indexed by
   ifIndex and logical link address such as the DLCI or VPI/VCI).  In
   the absence of interworking, two endpoints are cross-connected via a
   technology-specific cross connect table (e.g., the
   atmVcCrossConnectTable in the ATM MIB).  However, a connection
   between a frame relay endpoint and an ATM endpoint requires a cross-
   connect in the ATM IWF MIB.

   The following sections describe the relationship between the
   technology-specific MIBs and the FR/ATM PVC Service IWF MIB.






Rehbehn, et al.             Standards Track                     [Page 5]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


3.3.1.  Frame Relay Service MIB

   Frame relay PVC endpoints are provisioned as rows in the Frame Relay
   Services MIB [19] endpoint table.

   Each frame relay PVC endpoint is described in the frPVCEndptTable.  A
   connection between two frame relay endpoints is described by an entry
   in the frame relay PVC cross-connect table frPVCConnectTable.  The
   frPVCEndptConnectIdentifier object of each endpoint points to the
   frPVCConnectTable cross-connect table row for the connection.

   In the case of an inter-worked connection, the
   frPVCEndptConnectIdentifier object is set to zero.  Instead, the
   frPVCEndptAtmIwfConnIndex object is set to the index of the FR/ATM
   IWF cross-connect table row.

   The frame relay PVC cross-connect table (frPVCConnectTable) does not
   contain an entry for the FR/ATM inter-worked connection.

   Note that the frPVCEndptConnectIdentifier and
   frPVCEndptAtmIwfConnIndex objects are set by the system as a side-
   effect of cross-connect establishment.  Consequently, these objects
   are read-only.

3.3.2.  Frame Relay DTE MIB

   The Frame Relay DTE MIB described in [24] has no relevance to the
   FR/ATM PVC Service IWF MIB.

3.3.3.  ATM MIB

   ATM PVC endpoints are provisioned as rows in the ATM MIB [21] virtual
   connection link table.

   Each ATM connection endpoint is described in the atmVclTable.  A
   connection between two ATM endpoints is described by an entry in the
   ATM VCL cross-connect table atmVcCrossConnectTable.  The
   atmVclCrossConnectIdentifier object of each endpoint points to the
   atmVcCrossConnectTable row for the connection.

   In the case of an inter-worked connection, the
   atmVclCrossConnectIdentifier object is set to zero.  Instead, the
   frAtmIwfVclCrossConnectIdentifier object in the frAtmIwfVclEntry is
   set to the index of the applicable FR/ATM IWF cross-connect table
   row.






Rehbehn, et al.             Standards Track                     [Page 6]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   Note that the frAtmIwfVclCrossConnectIdentifier object is defined not
   in the ATM MIB but in Section 5 of this MIB.  Specifically, the
   object is defined as a column object in a table that AUGMENTs the ATM
   MIB VCL table.

   The ATM VCL cross-connect table (atmVcCrossConnectTable) does not
   contain an entry for the inter-worked connection.

   Note that the atmVclCrossConnectIdentifier and
   frAtmIwfVclCrossConnectIdentifier objects are set by the system as a
   side-effect of cross-connect establishment.  Consequently, these
   objects are read-only.

3.3.4.  IF MIB

   The ifIndex defined in the IF MIB [22] identifies the specific frame
   relay and ATM endpoint interfaces.  The values frAtmIwfConnAtmPort
   and frAtmIwfConnFrPort are used in this MIB as components in the
   index list for the frAtmIwfConnectionTable rows.

3.4.  Point to Multipoint Considerations

   This MIB supports IWF implementations providing point-to-multipoint
   functionality. All rows of the cross-connect table indexed by the
   same frAtmIwfConnIndex MUST utilize the same
   frAtmIwfConnectionDescriptor value.

   A group of cross-connect table entries indexed by the same
   frAtmIwfConnIndex value MUST agree on which service the multipoint
   operation is offered. Two cases are possible:

   (1) Many frame relay PVCs cross-connected to one ATM PVC, or

   (2) One frame relay PVC cross-connected to many ATM PVCs

3.5.  Theory of Operation

3.5.1.  Creation Process

   Multiple steps are required to create a frame relay to ATM cross-
   connection.  First, rows must be created in the following tables:

   (1) The Frame Relay Service MIB frPVCEndptTable

   (2) The ATM MIB atmVclTable

   (3) The FR/ATM Service IWF MIB frAtmIwfConnectionDescriptorTable




Rehbehn, et al.             Standards Track                     [Page 7]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   (4) The FR/ATM Service IWF MIB frAtmIwfConnectionTable

   Second, the newly created rows are cross-linked.

   Finally, the administrative and operational status objects are set to
   'up(1)'.

   A step-by-step example is provided to illustrate the creation
   process.  In this example, the term "Manager" refers to a network
   management system that issues SNMP protocol actions to an "Agent".
   The agent is integrated with the system that implements the frame
   relay to ATM service IWF.  In this example, the following cross-
   connection is created:

                  +-----------------------------------+
   +---------+    |       FR/ATM PVC Service IWF      |
   | Frame   |    |   ------------------------------  |    +-----------+
   | Relay   |  +--------> frAtmIwfConnIndex K <--------+  |   ATM     |
   |Endpoint |  | |               V                   | |  | Endpoint  |
   | ------- |  | |               |                   | |  | --------- |
   | DLCI X  |  | |  +------------+                   | |  |VPI.VCI Q.R|
   |  on     |<-+ |  |                                | +->|    on     |
   |ifIndex Y|    |  V                                |    | ifIndex S |
   +---------+    |frAtmIwfConnectionDescriptorIndex L|    +-----------+
                  +-----------------------------------+

   Step 1 - Create the frame relay PVC endpoint

   a) Manager requests creation of a new row in the frPVCEndptTable

   b) Agent receives management request to create a row in
      frPVCEndptTable for the frame relay side

   c) A new row is created in frPVCEndptTable as follows:

      -  frPVCEndptConnectIdentifier initialized to zero

      -  frPVCEndptAtmIwfConnIndex initialized to zero

      -  remaining row objects initialized as needed for DLCI X on
         ifIndex Y

   Step 2 - Create the ATM PVC endpoint

   a) Agent receives management request to create a row in atmVclTable
      for the ATM side





Rehbehn, et al.             Standards Track                     [Page 8]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   b) A new row is created in atmVclTable and frAtmIwfVclTable (the
      AUGMENT to the atmVclTable) as follows:

      -  atmVclCrossConnectIdentifier initialized to zero

      -  frAtmIwfVclCrossConnectIdentifier initialized to zero

      -  atmVclConnKind initialized to pvc(1)

      -  remaining row objects initialized as needed for VPI.VCI Q.R on
         ifIndex S

   Step 3 - Create the FR/ATM connection descriptor

   a) If an existing connection descriptor is appropriate for the new
      connection, go to Step 4 using the selected connection descriptor
      index value L

   b) Manager requests a new connection descriptor index value by
      reading frAtmIwfConnectionDescriptorIndexNext from the agent

   c) Agent receives GET request for
      frAtmIwfConnectionDescriptorIndexNext and responds with the next
      available value L

   d) Manager requests a new connection descriptor row entry using the
      value L as the index

   e) Agent receives SET request to create the
      frAtmIwfConnectionDescriptorTable row entry causes the system to
      create a row in the table.

   Step 4 - Create the FR/ATM cross-connect

   a) Manager requests a new cross-connect index value by reading
      frAtmIwfConnIndexNext from the agent

   b) Agent receives GET request for frAtmIwfConnIndexNext and responds
      with the next available value K

   c) Manager requests a new cross-connect row entry using the value K
      as the index

   d) Agent receives SET request to create the frAtmIwfConnectionTable
      row entry (note: the frame relay and ATM PVC endpoints MUST exist
      and be specified as part of the index fields for the row
      'K.S.Q.R.Y.X')




Rehbehn, et al.             Standards Track                     [Page 9]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   e) System creates a row in frAtmIwfConnectionTable for the following
      indices:

      -  frAtmIwfConnIndex of K

      -  frAtmIwfConnAtmPort of S

      -  frAtmIwfConnVpi of Q

      -  frAtmIwfConnVci of R

      -  frAtmIwfConnFrPort of Y

      -  frAtmIwfConnDlci of X

      -  frAtmIwfConnectionDescriptor of L

   Step 5 - The system sets the frame relay PVC endpoint and ATM VCL
   endpoint to point to the FR/ATM cross-connect row (as a side-effect
   of Step 4).

   a) System sets frPVCEndptAtmIwfConnIndex to K

   b) System sets frAtmIwfVclCrossConnectIdentifier to K

   Step 6 - Manager signals activation by issuing a SET for the
   frAtmIwfConnAdminStatus object using the value of 'up(1)'

   Step 7 - Agent receives SET request for frAtmIwfConnAdminStatus and
   executes internal system mechanisms to activate each PVC segment and
   the IWF cross-connect. The successful activation permits the agent to
   respond with 'up(1)' when a GET request is received for the following
   fields:

      -  frAtmIwfConnAtm2FrOperStatus

      -  frAtmIwfConnFr2AtmOperStatus

      -  atmVclOperStatus (Note: there is no comparable FRS MIB object)

3.5.2.  Destruction Process

   Destruction of the frame relay to ATM cross-connection is initiated
   by the network management system.  The agent's processing of the
   request stimulates implementation-specific system clean-up actions.
   Following removal of the row in the cross-connection table, the
   frAtmIwfVclCrossConnectIdentifier in the frAtmIwfVclTable (AUGMENT of




Rehbehn, et al.             Standards Track                    [Page 10]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   the ATM MIB endpoint table) and frPVCEndptAtmIwfConnIndex in the
   Frame Relay Service MIB endpoint table are both re-initialized to
   zero.

   A step-by-step example is provided to illustrate the destruction
   process.

   Step 1 - Manager requests destruction of an existing row in the
   frAtmIwfConnectionTable by setting frAtmIwfConnRowStatus to
   destroy(6)

   Step 2 - Agent receives the SET request and performs implementation-
   specific system clean-up actions for the cross-connection row

   Step 3 - System updates the relevant cross connect information for
   the frame relay PVC endpoint by setting frPVCEndptAtmIwfConnIndex to
   0

   Step 4 - System updates the relevant cross connect information for
   the ATM PVC endpoint as follows:

   a) System sets frAtmIwfVclCrossConnectIdentifier to 0

   b) System sets atmVclOperStatus to 'down(2)' (Note: there is no
      comparable FRS MIB object)

   Following the destruction of the FR/ATM cross-connection entry, the
   manager MAY set the frPVCConnectRowStatus and/or atmVclRowStatus to
   destroy(6) the associated endpoint entries.

3.5.3.  Modification Process

   At the discretion of the agent, a FR/ATM cross-connect may be
   reconfigured by adding and/or deleting leafs to/from the IWF topology
   as per the FR/ATM IWF cross-connect creation/destruction procedures.
   Reconfiguration of traffic/service category parameter values requires
   release of the FR/ATM IWF cross-connect before those parameter values
   may be changed for individual frame relay or ATM endpoint segments.

4.  Object Definitions

FR-ATM-PVC-SERVICE-IWF-MIB DEFINITIONS ::= BEGIN

IMPORTS
              MODULE-IDENTITY, OBJECT-TYPE,
              NOTIFICATION-TYPE,
              mib-2, Integer32, Counter32             FROM SNMPv2-SMI




Rehbehn, et al.             Standards Track                    [Page 11]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


              RowStatus, TimeStamp                    FROM SNMPv2-TC

              MODULE-COMPLIANCE, OBJECT-GROUP,
              NOTIFICATION-GROUP                      FROM SNMPv2-CONF

              AtmVpIdentifier, AtmVcIdentifier        FROM ATM-TC-MIB

              atmVclEntry                             FROM ATM-MIB

              InterfaceIndex                          FROM IF-MIB;

         frAtmIwfMIB MODULE-IDENTITY
             LAST-UPDATED "200009280000Z" -- September 28, 2000
             ORGANIZATION "IETF Frame Relay Service MIB Working Group"
             CONTACT-INFO
                 "WG Charter:
                    http://www.ietf.org/html.charters/frnetmib-charter
                  WG-email:
                    frnetmib@sunroof.eng.sun.com
                  Subscribe:
                    frnetmib-request@sunroof.eng.sun.com
                  Email Archive:
                    ftp://ftp.ietf.org/ietf-mail-archive/frnetmib

                  Chair:      Andy Malis
                              Vivace Networks, Inc.
                  Email:      Andy.Malis@vivacenetworks.com

                  WG editor:  Kenneth Rehbehn
                              Megisto Systems, Inc.
                  Email:      krehbehn@megisto.com

                  Co-author:  Orly Nicklass
                              RAD Data Communications Ltd.
                  EMail:      orly_n@rad.co.il

                  Co-author:  George Mouradian
                              AT&T Labs
                  EMail:      gvm@att.com"

             DESCRIPTION
                     "The MIB module for monitoring and controlling the
                     Frame Relay/ATM PVC Service Interworking
                     Function."

             --
             -- Revision History
             --



Rehbehn, et al.             Standards Track                    [Page 12]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


             REVISION "200009280000Z"
             DESCRIPTION
                  "Published as RFC 2955"

         ::= { mib-2 86 }

         --
         -- Object Identifiers
         --
            frAtmIwfMIBObjects      OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 1 }

            frAtmIwfTraps           OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 2 }
            frAtmIwfTrapsPrefix     OBJECT IDENTIFIER
                                         ::= { frAtmIwfTraps 0 }

            frAtmIwfConformance     OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 3 }
            frAtmIwfGroups          OBJECT IDENTIFIER
                                         ::= { frAtmIwfConformance 1 }
            frAtmIwfCompliances     OBJECT IDENTIFIER
                                         ::= { frAtmIwfConformance 2 }

         --
         --  The FR/ATM PVC Service IWF Group
         --
         --      The Frame Relay/ATM PVC Service Interworking Function
         --      Connection Table contains all connections utilizing
         --      the interworking function.
         --

         frAtmIwfConnIndexNext OBJECT-TYPE
              SYNTAX         Integer32 (0..2147483647)
              MAX-ACCESS     read-only
              STATUS         current
              DESCRIPTION
                     "This object contains an appropriate value to be
                     used for frAtmIwfConnIndex  when creating entries
                     in the frAtmIwfConnectionTable. The value 0
                     indicates that no unassigned entries are
                     available. To obtain the frAtmIwfConnIndexNext
                     value for a new entry, the manager issues a
                     management protocol retrieval operation to obtain
                     the current value of this object.  After each
                     retrieval, the agent should modify the value to
                     the next unassigned index."
              ::= { frAtmIwfMIBObjects 1 }



Rehbehn, et al.             Standards Track                    [Page 13]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


         frAtmIwfConnectionTable OBJECT-TYPE
             SYNTAX      SEQUENCE OF FrAtmIwfConnectionEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A table in which each row represents a Frame
                     Relay/ATM interworking connection."
             ::= { frAtmIwfMIBObjects 2 }

         frAtmIwfConnectionEntry OBJECT-TYPE
             SYNTAX      FrAtmIwfConnectionEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The FrAtmIwfConnectionEntry provides an entry for
                     an interworking connection between a frame relay
                     PVC and one or more ATM PVCs, or an ATM PVC and
                     one or more frame relay PVCs.  A single frame
                     relay PVC connected to a single ATM PVC is
                     referred to as a `point-to-point' connection and
                     is represented by a single row in the FR/ATM IWF
                     Connection Table.  The case of a single frame
                     relay PVC connected to multiple ATM PVCs (or
                     single ATM PVC connected to multiple frame relay
                     PVCs) is referred to as a `point-to-multipoint'
                     connection and is represented by multiple rows in
                     the FR/ATM IWF Connection Table.

                     The object frAtmIwfConnIndex uniquely identifies
                     each point-to-point or point-to-multipoint
                     connection.  The manager obtains the
                     frAtmIwfConnIndex value by reading the
                     frAtmIwfConnIndexNext object.

                     After a frAtmIwfConnIndex is assigned for the
                     connection, the manager creates one or more rows
                     in the Cross Connect Table; one for each cross-
                     connection between the frame relay PVC and an ATM
                     PVC. In the case of `point-to-multipoint'
                     connections, all rows are indexed by the same
                     frAtmIwfConnIndex value and MUST refer to the same
                     frame relay PVC or ATM PVC respectively.  An entry
                     can be created only when at least one pair of
                     frame relay and ATM PVCs exist.

                     A row can be established by one-step set-request
                     with all required parameter values and
                     frAtmIwfConnRowStatus set to createAndGo(4). The



Rehbehn, et al.             Standards Track                    [Page 14]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     Agent should perform all error checking as needed.
                     A pair of cross-connected PVCs, as identified by a
                     particular value of the indexes, is released by
                     setting frAtmIwfConnRowStatus to destroy(6). The
                     Agent may release all associated resources. The
                     manager may remove the related PVCs thereafter.
                     Indexes are persistent across reboots of the
                     system."
             INDEX   { frAtmIwfConnIndex,
                       frAtmIwfConnAtmPort,
                       frAtmIwfConnVpi,
                       frAtmIwfConnVci,
                       frAtmIwfConnFrPort,
                       frAtmIwfConnDlci
                     }
             ::= { frAtmIwfConnectionTable 1 }

         FrAtmIwfConnectionEntry ::=
             SEQUENCE {
                 frAtmIwfConnIndex                      Integer32,
                 frAtmIwfConnAtmPort                    InterfaceIndex,
                 frAtmIwfConnVpi                        AtmVpIdentifier,
                 frAtmIwfConnVci                        AtmVcIdentifier,
                 frAtmIwfConnFrPort                     InterfaceIndex,
                 frAtmIwfConnDlci                       Integer32,
                 frAtmIwfConnRowStatus                  RowStatus,
                 frAtmIwfConnAdminStatus                INTEGER,
                 frAtmIwfConnAtm2FrOperStatus           INTEGER,
                 frAtmIwfConnAtm2FrLastChange           TimeStamp,
                 frAtmIwfConnFr2AtmOperStatus           INTEGER,
                 frAtmIwfConnFr2AtmLastChange           TimeStamp,
                 frAtmIwfConnectionDescriptor           Integer32,
                 frAtmIwfConnFailedFrameTranslate       Counter32,
                 frAtmIwfConnOverSizedFrames            Counter32,
                 frAtmIwfConnFailedAal5PduTranslate     Counter32,
                 frAtmIwfConnOverSizedSDUs              Counter32,
                 frAtmIwfConnCrcErrors                  Counter32,
                 frAtmIwfConnSarTimeOuts                Counter32
         }

         frAtmIwfConnIndex  OBJECT-TYPE
             SYNTAX      Integer32  (1..2147483647)
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A unique value for each point-to-point or point-
                     to-multipoint connection.  The manager obtains the
                     frAtmIwfConnIndex value by reading the



Rehbehn, et al.             Standards Track                    [Page 15]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     frAtmIwfConnIndexNext object.  A point-to-
                     multipoint connection will be represented in the
                     frAtmIwfConnectionTable with multiple entries that
                     share the same frAtmIwfConnIndex value."
             ::= { frAtmIwfConnectionEntry 1 }

         frAtmIwfConnAtmPort OBJECT-TYPE
             SYNTAX      InterfaceIndex
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The index in the ifTable that identifies the ATM
                     port for this interworking connection."
             ::= { frAtmIwfConnectionEntry 2 }

         frAtmIwfConnVpi OBJECT-TYPE
             SYNTAX      AtmVpIdentifier
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The VPI of the ATM PVC end point for this
                      interworking connection."
             ::= { frAtmIwfConnectionEntry 3 }

         frAtmIwfConnVci OBJECT-TYPE
             SYNTAX      AtmVcIdentifier
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The VCI of the ATM PVC end point for this
                     interworking
                      connection."
             ::= { frAtmIwfConnectionEntry 4 }

         frAtmIwfConnFrPort OBJECT-TYPE
             SYNTAX      InterfaceIndex
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The index in the ifTable that identifies the
                     frame relay port for this interworking
                     connection."
             ::= { frAtmIwfConnectionEntry 5 }

         frAtmIwfConnDlci OBJECT-TYPE
             SYNTAX      Integer32 (16..4194303)
             MAX-ACCESS  not-accessible
             STATUS      current



Rehbehn, et al.             Standards Track                    [Page 16]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


             DESCRIPTION
                     "The DLCI that identifies the frame relay PVC end
                     point for this interworking connection."
             ::= { frAtmIwfConnectionEntry 6 }

         frAtmIwfConnRowStatus OBJECT-TYPE
             SYNTAX      RowStatus
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The table row may be created with
                     'createAndWait(5)' or 'createAndGo(4)'.
                     To activate a connection entry, a valid connection
                     descriptor MUST be established in the
                     frAtmIwfConnectionDescriptor object.

                     This object is set to 'destroy(6)' to delete the
                     table row.  Before the table row is destroyed, the
                     OperStatus/AdminStatus of the corresponding
                     endpoints MUST be 'down(2)'.  The deactivation of
                     the ATM endpoint MAY occur as a side-effect of
                     deleting the FR/ATM IWF cross-connection table
                     row.  Otherwise, 'destroy(6)' operation MUST fail
                     (error code 'inconsistentValue')."
             ::= { frAtmIwfConnectionEntry 7 }

         frAtmIwfConnAdminStatus OBJECT-TYPE
             SYNTAX      INTEGER { up(1), down(2) }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The desired operational state for this FR/ATM
                     interworked connection.

                     up(1)       = Activate the connection. Before the
                                   activation can be completed, the
                                   OperStatus/AdminStatus of the
                                   corresponding endpoints MUST be
                                   'up(1)'.  The activation of the
                                   corresponding endpoints MAY occur as
                                   a side-effect of activating the
                                   FR/ATM IWF cross-connection.

                     down(2)     = Deactivate the connection. Before
                                   the deactivation can be completed,
                                   the atmVclAdminStatus of the
                                   corresponding ATM endpoint MUST be
                                   'down(2)'.  The deactivation of the



Rehbehn, et al.             Standards Track                    [Page 17]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                                   ATM endpoint MAY occur as a
                                   side-effect of deactivating the
                                   FR/ATM IWF cross-connection."
             ::= { frAtmIwfConnectionEntry 8 }

         frAtmIwfConnAtm2FrOperStatus     OBJECT-TYPE
             SYNTAX      INTEGER { up(1), down(2) }
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The current operational state of this
                     interworking connection in the ATM to frame
                     relay direction."
             ::= { frAtmIwfConnectionEntry 9 }

         frAtmIwfConnAtm2FrLastChange  OBJECT-TYPE
             SYNTAX      TimeStamp
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The value of sysUpTime at the time this
                     interworking connection entered its current
                     operational state in the ATM to FR direction.  If
                     the current state was entered prior to the last
                     re-initialization of the local network management
                     subsystem, then this object contains a zero
                     value."
             ::= { frAtmIwfConnectionEntry 10 }

         frAtmIwfConnFr2AtmOperStatus     OBJECT-TYPE
             SYNTAX      INTEGER { up(1), down(2) }
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The current operational state of this
                     interworking connection in the frame relay
                     to ATM direction."
             ::= { frAtmIwfConnectionEntry 11 }

         frAtmIwfConnFr2AtmLastChange  OBJECT-TYPE
             SYNTAX      TimeStamp
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The value of sysUpTime at the time this
                     interworking connection entered its current
                     operational state in the FR to ATM direction.  If
                     the current state was entered prior to the last



Rehbehn, et al.             Standards Track                    [Page 18]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     re-initialization of the local network management
                     subsystem, then this object contains a zero
                     value."
             ::= { frAtmIwfConnectionEntry 12 }

         frAtmIwfConnectionDescriptor  OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The value represents a pointer to the relevant
                     descriptor in the IWF descriptor table.  An
                     attempt to set this value to an inactive or non-
                     existent row in the Connection Descriptor Table
                     MUST fail (error code 'inconsistentValue')."
             ::= { frAtmIwfConnectionEntry 13 }

         frAtmIwfConnFailedFrameTranslate OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "Frames"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "This object counts the number of frames discarded
                     by the IWF because, while operating in Translation
                     Mode, the IWF is unable to decode the incoming
                     frame payload header according to the mapping
                     rules. (i.e., payload header not recognized by the
                     IWF).

                     Frame relay frames are received in the frame relay
                     to ATM direction of the PVC.

                     When operating in Transparent Mode, the IWF MUST
                     return noSuchInstance."
                       REFERENCE
                                "FRF.8 [17], Section 5.3.1"
                       ::= { frAtmIwfConnectionEntry 14 }

         frAtmIwfConnOverSizedFrames OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "Frames"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "Count of frames discarded by the IWF because the
                     frame is too large to be processed by the AAL5
                     segmentation procedure.  Specifically, the frame



Rehbehn, et al.             Standards Track                    [Page 19]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     does not conform to the size specified in the
                     atmVccAal5CpcsTransmitSduSize object associated
                     with the atmVclEntry at the ATM endpoint.
                     Frame relay frames are received in the frame relay
                     to ATM direction of the PVC."
                       REFERENCE
                                "ATM MIB [21], atmVclTable
                                 FRF.8 [17], 5.3.1.4"
                       ::= { frAtmIwfConnectionEntry 15 }

         frAtmIwfConnFailedAal5PduTranslate OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "PDUs"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "This attribute counts the number of AAL5 PDUs
                     discarded by the IWF because, while operating in
                     Translation Mode, the IWF is unable to decode the
                     incoming AAL5 PDU payload header according to the
                     mapping rules. (i.e., payload header not
                     recognized by the IWF).

                     AAL5 PDUs are received in the ATM to frame relay
                     direction of the PVC.

                     When operating in Transparent Mode, the IWF MUST
                     return noSuchInstance."
                       REFERENCE
                                "FRF.8 [17], Section 5.3.1"
                       ::= { frAtmIwfConnectionEntry 16 }

         frAtmIwfConnOverSizedSDUs OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "SDUs"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "Count of AAL5 SDUs discarded by the IWF because
                     the SDU is too large to be forwarded on the frame
                     relay segment of the connection.  Specifically,
                     the frame does not conform to the size specified
                     in the frLportFragSize object of the FRS MIB [19].

                     AAL5 PDUs are received in the ATM to frame relay
                     direction of the PVC."
                       REFERENCE
                                "FRS MIB [19], frLportTable



Rehbehn, et al.             Standards Track                    [Page 20]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                                 FRF.8 [17], 5.3.1.4"
                       ::= { frAtmIwfConnectionEntry 17 }

         frAtmIwfConnCrcErrors OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "PDUs"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The number of AAL5 CPCS PDUs received with CRC-32
                     errors on this AAL5 VCC at the IWF.

                     AAL5 PDUs are received in the ATM to frame relay
                     direction of the PVC."
                       REFERENCE
                                "ATM MIB [21], atmVclTable"
                       ::= { frAtmIwfConnectionEntry 18 }

         frAtmIwfConnSarTimeOuts OBJECT-TYPE
             SYNTAX      Counter32
             UNITS       "PDUs"
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "The number of partially re-assembled AAL5 CPCS
                     PDUs which were discarded on this AAL5 VCC at the
                     IWF because they were not fully re-assembled
                     within the required time period.  If the re-
                     assembly timer is not supported, then this object
                     contains a zero value.

                     AAL5 PDUs are received in the ATM to frame relay
                     direction of the PVC."
                       REFERENCE
                                "ATM MIB [21], atmVclTable"
                       ::= { frAtmIwfConnectionEntry 19 }

         --
         -- The FR/ATM PVC Service IWF Connection Descriptor Group
         --
         --     The Frame Relay/ATM PVC Service Interworking Function
         --     Connection Descriptor table.  A descriptor provides the
         --     attributes for a type of interworked connection.
         --

         frAtmIwfConnectionDescriptorIndexNext OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  read-only



Rehbehn, et al.             Standards Track                    [Page 21]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


              STATUS      current
              DESCRIPTION
                     "This object contains an appropriate value to be
                     used for frAtmIwfConnectionDescriptorIndex  when
                     creating entries in the
                     frAtmIwfConnectionDescriptorTable. The value 0
                     indicates that no unassigned entries are
                     available. To obtain the
                     frAtmIwfConnectionDescriptorIndexNext value for a
                     new entry, the manager issues a management
                     protocol retrieval operation to obtain the current
                     value of this object.  After each retrieval, the
                     agent should modify the value to the next
                     unassigned index."
              ::= { frAtmIwfMIBObjects 3 }

         frAtmIwfConnectionDescriptorTable OBJECT-TYPE
             SYNTAX      SEQUENCE OF FrAtmIwfConnectionDescriptorEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A table in which each row represents a descriptor
                     for one type of Frame Relay/ATM interworking
                     connection.  A descriptor may be assigned to zero
                     or more FR/ATM PVC service IWF connections."
             ::= { frAtmIwfMIBObjects 4 }

         frAtmIwfConnectionDescriptorEntry OBJECT-TYPE
             SYNTAX      FrAtmIwfConnectionDescriptorEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "An entry for a descriptor in an interworking
                     connection between a frame relay PVC and an ATM
                     PVC."
             INDEX   { frAtmIwfConnectionDescriptorIndex  }
             ::= { frAtmIwfConnectionDescriptorTable 1 }

         FrAtmIwfConnectionDescriptorEntry ::=
             SEQUENCE {
                 frAtmIwfConnectionDescriptorIndex      Integer32,
                 frAtmIwfConnDescriptorRowStatus        RowStatus,
                 frAtmIwfConnDeToClpMappingMode         INTEGER,
                 frAtmIwfConnClpToDeMappingMode         INTEGER,
                 frAtmIwfConnCongestionMappingMode      INTEGER,
                 frAtmIwfConnEncapsulationMappingMode   INTEGER,
                 frAtmIwfConnEncapsulationMappings      BITS,
                 frAtmIwfConnFragAndReassEnabled        INTEGER,



Rehbehn, et al.             Standards Track                    [Page 22]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                 frAtmIwfConnArpTranslationEnabled      INTEGER
         }

         frAtmIwfConnectionDescriptorIndex OBJECT-TYPE
             SYNTAX      Integer32 (1..2147483647)
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A unique value to identify a descriptor in the
                     table "
             ::= { frAtmIwfConnectionDescriptorEntry 1 }

         frAtmIwfConnDescriptorRowStatus OBJECT-TYPE
             SYNTAX      RowStatus
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The status of this table row.  This object is
                     used to create or delete an entry in the
                     descriptor table.

                     Creation of the row requires a row index (see
                     frAtmIwfConnectionDescriptorIndexNext).  If not
                     explicitly set or in existence, all other columns
                     of the row will be created and initialized to the
                     default value.  During creation, this object MAY
                     be set to 'createAndGo(4)' or 'createAndWait(5)'.
                     The object MUST contain the value 'active(1)'
                     before any connection table entry references the
                     row.

                     To destroy a row in this table, this object is set
                     to the 'destroy(6)' action.  Row destruction MUST
                     fail (error code 'inconsistentValue') if any
                     connection references the row."
             ::= { frAtmIwfConnectionDescriptorEntry 2 }

         frAtmIwfConnDeToClpMappingMode OBJECT-TYPE
             SYNTAX      INTEGER {
                            mode1(1),
                            mode2Const0(2),
                            mode2Const1(3)
                         }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "This object describes which mode of translation
                     is in use for loss priority mapping in the frame



Rehbehn, et al.             Standards Track                    [Page 23]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     relay to ATM direction.

                     mode1(1)        = the DE field in the Q.922 core
                                       frame shall be mapped to the ATM
                                       CLP field of every cell
                                       generated by the segmentation
                                       process of the AAL5 PDU
                                       containing the information of
                                       that frame.

                     mode2Contst0(2) = the ATM CLP field of every cell
                                       generated by the segmentation
                                       process of the AAL5 PDU
                                       containing the information of
                                       that frame shall be set to
                                       constant 0.

                     mode2Contst1(3) = the ATM CLP field of every cell
                                       generated by the segmentation
                                       process of the AAL5 PDU
                                       containing the information of
                                       that frame shall be set to
                                       constant 1."
             REFERENCE
                      "FRF.8 [17], Section 4.2.1"
             DEFVAL { mode1 }
             ::= { frAtmIwfConnectionDescriptorEntry 3 }

         frAtmIwfConnClpToDeMappingMode OBJECT-TYPE
             SYNTAX      INTEGER {
                           mode1(1),
                           mode2Const0(2),
                           mode2Const1(3)
                         }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "This object describes which mode of translation
                     is in use for loss priority mapping in the ATM to
                     frame relay direction.

                     mode1(1)       = if one or more cells in a frame
                                      has its CLP field set, the DE
                                      field of the Q.922 core frame
                                      should be set.

                     mode2Const0(2) = the DE field of the Q.922 core
                                      frame should be set to the



Rehbehn, et al.             Standards Track                    [Page 24]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                                      constant 0.

                     mode2Const1(3) = the DE field of the Q.922 core
                                      frame should be set to the
                                      constant 1."
             REFERENCE
                      "FRF.8 [17], Section 4.2.2"
             DEFVAL { mode1 }
             ::= { frAtmIwfConnectionDescriptorEntry 4 }

         frAtmIwfConnCongestionMappingMode OBJECT-TYPE
             SYNTAX      INTEGER {
                            mode1(1),
                            mode2(2)
                         }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "This object describes which mode of translation
                     is in use for forward congestion indication
                     mapping in the frame relay to ATM direction.

                     mode1(1) = The FECN field in the Q.922 core frame
                                shall be mapped to the ATM EFCI field
                                of every cell generated by the
                                segmentation process of the AAL5 PDU
                                containing the information of that
                                frame.

                     mode2(2) = The FECN field in the Q.922 core frame
                                shall not be mapped to the ATM EFCI
                                field of cells generated by the
                                segmentation process of the AAL5 PDU
                                containing the information of that
                                frame. The EFCI field is always set to
                                'congestion not experienced'.

                     In both of the modes above, if there is congestion
                     in the forward direction in the ATM layer within
                     the IWF, then the IWF can set the EFCI field to
                     'congestion experienced'."
             REFERENCE
                         "FRF.8 [17], Section 4.3.1.1"
             DEFVAL      { mode1 }
             ::= { frAtmIwfConnectionDescriptorEntry 5 }

         frAtmIwfConnEncapsulationMappingMode OBJECT-TYPE
             SYNTAX      INTEGER {



Rehbehn, et al.             Standards Track                    [Page 25]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                            transparentMode(1),
                            translationMode(2),
                            translationModeAll(3)
                         }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "This object indicates whether the mapping of
                     upper layer protocol encapsulation is enabled on
                     this interworking connection.

                     transparentMode(1) = Forward the encapsulations
                                          unaltered.

                     translationMode(2) = Perform mapping between the
                                          two encapsulations due to the
                                          incompatibilities of the two
                                          methods. Mapping is provided
                                          for a subset of the potential
                                          encapsulations as itemized in
                                          frAtmIwfConnEncapsulationMapp
                                          ings.

                     translationModeAll(3) = Perform mapping between
                                          the two encapsulations due to
                                          the incompatibilities of the
                                          two methods. All
                                          encapsulations are
                                          translated."
             REFERENCE
                         "FRF.8 [17], Section 5.3"
             DEFVAL      { transparentMode }
             ::= { frAtmIwfConnectionDescriptorEntry 6 }

         frAtmIwfConnEncapsulationMappings OBJECT-TYPE
             SYNTAX      BITS {
                    none (0),
                    bridgedPdus(1),
                    bridged802dot6(2),
                    bPdus(3),
                    routedIp(4),
                    routedOsi(5),
                    otherRouted(6),
                    x25Iso8202(7),
                    q933q2931(8) }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION



Rehbehn, et al.             Standards Track                    [Page 26]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     "If upper layer protocol encapsulation mapping is
                     enabled on this interworking connection, then this
                     attribute enumerates which of the encapsulation
                     mappings are supported.

                     none(0)           = Transparent mode operation
                     bridgedPdus(1)    = PID: 0x00-01,-07,-02 or -08
                     bridged802dot6(2) = PID: 0x00-0B
                     bPdus(3)          = PID: 0x00-0E or -0F
                     routedIp(4)       = NLPID: OxCC
                     routedOsi(5)      = NLPID: Ox81, 0x82 or 0x83
                     otherRouted(6)    = Other routed protocols
                     x25Iso8202(7)     = X25
                     q933q2931(8)      = Q.933 and Q.2931"
             REFERENCE
                         "FRF.8 [17], Section 5.3.1"
             DEFVAL      { { none } }
             ::= { frAtmIwfConnectionDescriptorEntry 7 }

         frAtmIwfConnFragAndReassEnabled OBJECT-TYPE
             SYNTAX      INTEGER { enabled(1),  disabled(2)}
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The attribute indicates whether fragmentation and
                     reassembly is enabled for this connection."
             REFERENCE
                         "FRF.8 [17], Section 5.3.1.4"
             DEFVAL      { disabled }
             ::= { frAtmIwfConnectionDescriptorEntry 8 }

         frAtmIwfConnArpTranslationEnabled OBJECT-TYPE
             SYNTAX      INTEGER { enabled(1),  disabled(2)}
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The attribute indicates whether ARP translation
                     is enabled for this connection."
             REFERENCE
                         "FRF.8 [17], Section 5.4"
             DEFVAL      { disabled }
             ::= { frAtmIwfConnectionDescriptorEntry 9 }

         --
         -- Augmentation of ATM MIB VCL Endpoint Table (atmVclTable)
         --
         frAtmIwfVclTable OBJECT-TYPE
             SYNTAX      SEQUENCE OF FrAtmIwfVclEntry



Rehbehn, et al.             Standards Track                    [Page 27]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The FR/ATM IWF VCL Table augments the ATM MIB VCL
                     Endpoint table."
             ::= { frAtmIwfMIBObjects 5 }

         frAtmIwfVclEntry OBJECT-TYPE
             SYNTAX      FrAtmIwfVclEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "Entries in this table are created only by the
                     agent. One entry exists for each ATM VCL managed
                     by the agent."
             AUGMENTS    { atmVclEntry }
             ::= { frAtmIwfVclTable 1 }

         FrAtmIwfVclEntry ::= SEQUENCE {
             frAtmIwfVclCrossConnectIdentifier    Integer32
         }

         frAtmIwfVclCrossConnectIdentifier OBJECT-TYPE
             SYNTAX      Integer32  (1..2147483647)
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                     "This object contains the index value of the
                     FR/ATM cross-connect table entry used to link the
                     ATM VCL with a frame relay PVC.

                     Each row of the atmVclTable that is not cross-
                     connected with a frame relay PVC MUST return the
                     value zero when this object is read.

                     In the case of (frame relay) point to (ATM)
                     multipoint, multiple ATM VCLs will have the same
                     value of this object, and all their cross-
                     connections are identified by entries that are
                     indexed by the same value of
                     frAtmIwfVclCrossConnectIdentifier in the
                     frAtmIwfConnectionTable of this MIB module.

                     The value of this object is initialized by the
                     agent after the associated entries in the
                     frAtmIwfConnectionTable have been created."
             ::= { frAtmIwfVclEntry 1 }




Rehbehn, et al.             Standards Track                    [Page 28]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


         --
         -- Frame Relay/ATM PVC Service Interworking NOTIFICATION
         --

         frAtmIwfConnStatusChange NOTIFICATION-TYPE
             OBJECTS {   frAtmIwfConnAdminStatus,
                         frAtmIwfConnAtm2FrOperStatus,
                         frAtmIwfConnFr2AtmOperStatus
                      }
             STATUS      current
             DESCRIPTION
                     "An indication that the status of this
                     interworking connection has changed."
             ::= { frAtmIwfTrapsPrefix 1 }

         --
         -- Conformance Information
         --

         --
         -- Compliance Statement For Equipment
         --

         frAtmIwfEquipmentCompliance MODULE-COMPLIANCE
             STATUS      current
             DESCRIPTION
                     "The compliance statement for equipment that
                     implements the FR/ATM Interworking MIB."

             MODULE -- this module
                 MANDATORY-GROUPS { frAtmIwfBasicGroup,
                                    frAtmIwfConnectionDescriptorGroup,
                                    frAtmIwfAtmVclTableAugmentGroup,
                                    frAtmIwfNotificationsGroup }

                 OBJECT      frAtmIwfConnDeToClpMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 DESCRIPTION
                     "Only support for Mode 1 is REQUIRED."

                 OBJECT      frAtmIwfConnClpToDeMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 DESCRIPTION
                     "Only support for Mode 1 is REQUIRED."

                 OBJECT      frAtmIwfConnCongestionMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 DESCRIPTION



Rehbehn, et al.             Standards Track                    [Page 29]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     "Only support for Mode 1 is REQUIRED."

                 OBJECT      frAtmIwfConnEncapsulationMappingMode
                 SYNTAX      INTEGER { transparentMode(1) }
                 DESCRIPTION
                     "Support for Translation Mode is OPTIONAL."

                 OBJECT      frAtmIwfConnEncapsulationMappings
                 SYNTAX      BITS { none(0) }
                 DESCRIPTION
                     "The IWF may provide one, some or none of the
                     encapsulation translations defined in section
                     5.3.1 of FRF.8 [17]."

                 OBJECT      frAtmIwfConnFragAndReassEnabled
                 SYNTAX      INTEGER { disabled(2) }
                 DESCRIPTION
                     "Only support for Mode 1 is REQUIRED."

                 OBJECT      frAtmIwfConnArpTranslationEnabled
                 SYNTAX      INTEGER { disabled(2) }
                 DESCRIPTION
                     "Support for ARP Translation is NOT REQUIRED."

             ::= { frAtmIwfCompliances 1 }

         --
         -- Compliance Statement For Service (CNM Interface)
         --

         frAtmIwfServiceCompliance MODULE-COMPLIANCE
             STATUS  current
             DESCRIPTION
                     "The compliance statement for a CNM interface that
                     implements the FR/ATM Interworking MIB."

             MODULE  -- this module
                 MANDATORY-GROUPS { frAtmIwfBasicGroup,
                                    frAtmIwfConnectionDescriptorGroup,
                                    frAtmIwfAtmVclTableAugmentGroup,
                                    frAtmIwfNotificationsGroup }

                 --
                 -- Exceptions for each object type implemented for a
                 -- CNM view of the FR/ATM Interworking MIB
                 --
                 OBJECT      frAtmIwfConnAdminStatus
                 MIN-ACCESS  read-only



Rehbehn, et al.             Standards Track                    [Page 30]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                 DESCRIPTION
                     "Write access is not REQUIRED."

                 OBJECT      frAtmIwfConnDeToClpMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for Mode 1 is REQUIRED.  Other modes are
                     OPTIONAL.  Write access is NOT REQUIRED."

                 OBJECT      frAtmIwfConnClpToDeMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for Mode 1 is REQUIRED.  Other modes are
                     OPTIONAL.  Write access is NOT REQUIRED."

                 OBJECT      frAtmIwfConnCongestionMappingMode
                 SYNTAX      INTEGER { mode1(1) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for Mode 1 is REQUIRED.  Other modes are
                     OPTIONAL.  Write access is NOT REQUIRED."

                 OBJECT      frAtmIwfConnEncapsulationMappingMode
                 SYNTAX      INTEGER { transparentMode(1) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for Transparent Mode is REQUIRED.
                     Translation Mode is OPTIONAL.  Write access is not
                     required."

                 OBJECT      frAtmIwfConnEncapsulationMappings
                 SYNTAX      BITS { none(0) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "The IWF may provide one, some or none of the
                     encapsulation translations defined in section
                     5.3.1 of FRF.8 [17]. Write access is not
                     required."

                 OBJECT      frAtmIwfConnFragAndReassEnabled
                 SYNTAX      INTEGER { disabled(2) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for Fragmentation and Reassembly is NOT
                     REQUIRED.  Write access is not required."




Rehbehn, et al.             Standards Track                    [Page 31]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                 OBJECT      frAtmIwfConnArpTranslationEnabled
                 SYNTAX      INTEGER { disabled(2) }
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Support for ARP Translation is not required.
                     Write access is not required."

                 OBJECT      frAtmIwfConnRowStatus
                 MIN-ACCESS  read-only
                 DESCRIPTION
                     "Write access is not required."

             ::= { frAtmIwfCompliances 2 }

         --
         -- Units of Conformance
         --

         --
         -- Basic FR/ATM IWF PVC Connection Group
         --
         frAtmIwfBasicGroup    OBJECT-GROUP
             OBJECTS { frAtmIwfConnIndexNext,
                       frAtmIwfConnAdminStatus,
                       frAtmIwfConnAtm2FrOperStatus,
                       frAtmIwfConnAtm2FrLastChange,
                       frAtmIwfConnFr2AtmOperStatus,
                       frAtmIwfConnFr2AtmLastChange,
                       frAtmIwfConnectionDescriptor,
                       frAtmIwfConnFailedFrameTranslate,
                       frAtmIwfConnOverSizedFrames,
                       frAtmIwfConnFailedAal5PduTranslate,
                       frAtmIwfConnOverSizedSDUs,
                       frAtmIwfConnCrcErrors,
                       frAtmIwfConnSarTimeOuts,
                       frAtmIwfConnRowStatus }
             STATUS  current
             DESCRIPTION
                     "The collection of basic objects for configuration
                     and control of FR/ATM interworking connections."
             ::= { frAtmIwfGroups 1 }

         --
         -- FR/ATM IWF PVC Connection Descriptor Group
         --

         frAtmIwfConnectionDescriptorGroup    OBJECT-GROUP
             OBJECTS {



Rehbehn, et al.             Standards Track                    [Page 32]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                 frAtmIwfConnectionDescriptorIndexNext,
                 frAtmIwfConnDeToClpMappingMode,
                 frAtmIwfConnClpToDeMappingMode,
                 frAtmIwfConnCongestionMappingMode,
                 frAtmIwfConnEncapsulationMappingMode,
                 frAtmIwfConnEncapsulationMappings,
                 frAtmIwfConnFragAndReassEnabled,
                 frAtmIwfConnArpTranslationEnabled,
                 frAtmIwfConnDescriptorRowStatus
                 }
             STATUS  current
             DESCRIPTION
                     "The collection of basic objects for specification
                     of FR/ATM interworking connection descriptors."
             ::= { frAtmIwfGroups 2 }

         --
         -- ATM MIB VCL Endpoint Table Augmentation Group
         --

         frAtmIwfAtmVclTableAugmentGroup    OBJECT-GROUP
             OBJECTS {
                 frAtmIwfVclCrossConnectIdentifier
                 }
             STATUS  current
             DESCRIPTION
                     "The ATM MIB VCL Endpoint Table AUGMENT object
                     contained in the FR/ATM PVC Service Interworking
                     MIB."
             ::= { frAtmIwfGroups 3 }

         --
         -- Notification Group
         --

         frAtmIwfNotificationsGroup NOTIFICATION-GROUP
             NOTIFICATIONS { frAtmIwfConnStatusChange }
             STATUS  current
             DESCRIPTION
                     "The notification for FR/ATM interworking status
                     change."
             ::= { frAtmIwfGroups 4 }
         END








Rehbehn, et al.             Standards Track                    [Page 33]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


8.  Acknowledgments

   This document was produced by the Frame Relay Service MIB Working
   Group.

   The Editors thank Bert Wijnen, Kaj Tesink, Keith McCloghrie, and
   David Perkins for providing many helpful comments and suggestions.

9.  References

   [1]  Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
        Describing SNMP Management Frameworks", RFC 2571, April 1999.

   [2]  Rose, M. and K. McCloghrie, "Structure and Identification of
        Management Information for TCP/IP-based Internets", STD 16, RFC
        1155, May 1990.

   [3]  Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
        RFC 1212, March 1991.

   [4]  Rose, M., "A Convention for Defining Traps for use with the
        SNMP", RFC 1215, March 1991.

   [5]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Structure of Management Information
        Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

   [6]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
        RFC 2579, April 1999.

   [7]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
        58, RFC 2580, April 1999.

   [8]  Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.

   [9]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
        "Introduction to Community-based SNMPv2", RFC 1901, January
        1996.

   [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
        Mappings for Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1906, January 1996.






Rehbehn, et al.             Standards Track                    [Page 34]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
        Processing and Dispatching for the Simple Network Management
        Protocol (SNMP)", RFC 2572, April 1999.

   [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
        for version 3 of the Simple Network Management Protocol
        (SNMPv3)", RFC 2574, April 1999.

   [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
        Operations for Version 2 of the Simple Network Management
        Protocol (SNMPv2)", RFC 1905, January 1996.

   [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
        2573, April 1999.

   [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
        Control Model (VACM) for the Simple Network Management Protocol
        (SNMP)", RFC 2575, April 1999.

   [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
        to Version 3 of the Internet-standard Network Management
        Framework", RFC 2570, April 1999.

   [17] Frame Relay/ATM PVC Service Interworking Implementation
        Agreement, Frame Relay Forum, Document Number FRF.8.1, March,
        2000.

   [18] Noto, M., Spiegel, E. and K. Tesink, "Definitions of Textual
        Conventions and OBJECT-IDENTITIES for ATM Management", RFC 2514,
        February 1999.

   [19] Rehbehn, K. and D. Fowler, "Definitions of Managed Objects for
        Frame Relay Service", RFC 2954, October 2000.

   [20] Frame Relay/ATM PVC Network Interworking Implementation
        Agreement, Frame Relay Forum, Document Number FRF.5, December
        20, 1994.

   [21] Tesink, K., "Definitions of Managed Objects for ATM Management",
        RFC 2515, February 1999.

   [22] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
        RFC 2863, June 2000.

   [23] Bradner, S., "Key words for use in RFCs to Indicate Requirement
        Levels", BCP 14, RFC 2119, March 1997.





Rehbehn, et al.             Standards Track                    [Page 35]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


   [24] Brown, C. and F. Baker, "Management Information Base for Frame
        Relay DTEs Using SMIv2", RFC 2115, September 1997.

10.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   No managed objects in this MIB contain sensitive information.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model RFC 2574 [12] and the View-based
   Access Control Model RFC 2575 [15] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.






















Rehbehn, et al.             Standards Track                    [Page 36]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


11.  Authors' Addresses

   Kenneth Rehbehn
   Megisto Systems, Inc.
   20251 Century Boulevard
   Germantown, MD, USA 20874

   Phone: +1 (301) 515-3672
   EMail: krehbehn@megisto.com


   Orly Nicklass
   RAD Data Communications, Ltd.
   12 Hanechoshet St.
   Tel Aviv 69710
   Israel

   Phone: +972 (3) 6459588
   EMail: orly_n@rad.co.il


   George Mouradian
   AT&T Labs,  Room 1G-325
   101 Crawfords Corner Road
   Holmdel, NJ  USA  07733

   Phone: +1 908 949 7671
   EMail: gvm@att.com























Rehbehn, et al.             Standards Track                    [Page 37]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


12.  Intellectual Property Rights

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.






























Rehbehn, et al.             Standards Track                    [Page 38]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


13.  Full Copyright Statement

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Rehbehn, et al.             Standards Track                    [Page 39]