Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


XACT-CPLD: hi12:[Error]Keyword MC9500_PTERM_LIMIT in the CTL file is invalid.


Record #1047

Product Family:  Hardware

Product Line:  9500

Problem Title:
XACT-CPLD: hi12:[Error]Keyword MC9500_PTERM_LIMIT in the CTL file is
invalid.



Problem Description:
Using XACT-CPLD, the Design Manager may fail in the Implement Phase
 with the following error:

Optimizer/Partitioner Version 6.0.0
(c) Copyright 1989-1995 Xilinx Inc. All rights reserved.
hi12:[Error]Keyword MC9500_PTERM_LIMIT in the CTL file is invalid.
hi12:[Error]Keyword MC9500_INPUT_LIMIT in the CTL file is invalid.
Reading 9k.xff
hi7:[Error]Loading the XNF file failed.
Please correct the design XNF file and try again



Solution 1:

This can happen if the PATH and XACT variable are specified
incorrectly.

When targetting an XC9500 device using XACT-CPLD (DS560),
the XACT9000 directory MUST be before any other Xilinx software
in the PATH and XACT variable.

Example:

PATH <path_to_xact9000>;<any_other_paths>....
set xact=<path_to_xact9000>;<any_other_paths>

where <path_to_xact9000> is the location of the XACT-CPLD
software.  By default, this will be c:\xact9000.






End of Record #1047

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents