Record #1153 Product Family: Software Product Line: FPGA Core Problem Title: PPR: ERROR 1173: the file \path\dsn.lca associated with the LCA cell \path\dsn could not be found. Problem Description: Design Manager\Flow Engine stops with a pr 1173 error *** PPR: ERROR 1173: The file "\path\my_dsn.lca" associated with the LCA cell "\path\my_dsn" could not be found. PPR Terminating due to error status from subtool. Solution 1: If an LCA file on a drive other than the one the xproject is on is used as a gui de file then PPR will return *** PPR: ERROR 1173: The file "\path\my_dsn.lca" associated with the LCA cell "\path\my_dsn" could not be found. If a guide .lca file on either a second local drive or on a network drive is sel ected PPR may fail with the message above. The problem occurs because the software does not specify a drive before the path If the LCA file is moved to the same drive as the project then this error goes a way. End of Record #1153