XC5200: Typo reads "50-kW to 100-kW pull-up resistor" in 'The Programmable Logic Data Book', 7/96Record #1112
Product Family: Hardware XC5200: Typo reads "50-kW to 100-kW pull-up resistor" in 'The Programmable Logic Data Book', 7/96 Problem Description: There is a printing error on page 4-204 of the Xilinx 7/96 data book. At the bottom of the page, it reads: "Before and during configuration, all outputs that are not used for the configuration process are 3-stated with a 50-kW to 100-kW pull-up resistor. Solution 1: This should read: "Before and during configuration, all outputs that are not used for the configuration process are 3-stated with a 50-kohm to 100-kohm pull-up resistor." In reality, the most recent 5200 parts have a pullup of a range between 20K and 100K ohms End of Record #1112 - Last Modified: 09/11/97 14:37 |
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |