Answers Database


CPLD: XC9536 Does not have local feedback paths


Record #1400

Product Family: Hardware

Product Line: 9500

Product Part: 9536

Problem Title:
CPLD: XC9536 Does not have local feedback paths


Problem Description:
Urgency: Standard

General Description:
The XC9536 does not have local feedback paths like the other XC9500
devices.


Solution 1:

Page 3-20 of the 9/96 Xilinx Data Book indicates that the 16-bit
counter frequency, Fcnt, is 125Mhz. Since the XC9536 does not
have local feedback, the maximum frequency for a 16-bit counter in
an XC9536 is actually Fsystem, which is 100Mhz.

This is corrected in the latest databook as well as on the website.




End of Record #1400 - Last Modified: 01/03/00 10:36