Answers Database


CONCEPT2XIL Error #169: Port modes are not the same. The entity declaration needs to be updated


Record #1722

Product Family: Software

Product Line: Cadence

Product Part: concept2xil

Product Version: 2.16

Problem Title:
CONCEPT2XIL Error #169: Port modes are not the same. The entity declaration needs to be
updated



Problem Description:
Urgency: standard

General Description:

<OUTPUT> "Error #169: Port modes are not the same. The entity
declaration needs to be updated"
</OUTPUT>

You may see an error like this if the ports in the ENTITY
declaration created by HDL Direct for a body drawing do not
match the ports on the SYMBOL BODY for the same design block.

This error is seen in the 97A Cadence release.


Solution 1:

Bring up the symbol body in question in Concept and rewrite
(re-save) it. Doing this will ensure that the entity
corresponding to the symbol body will be regenerated based on
the current version of the symbol drawing:

    edit foo.body
    write




End of Record #1722 - Last Modified: 06/10/97 15:39