Answers Database
M1.3 XIL2CDS: ERROR : get_pwr_pin_name -- invalid pin # - '24' on target BGA package
Record #2439
Product Family: Software
Product Line: Cadence
Product Part: xil2cds
Problem Title:
M1.3 XIL2CDS: ERROR : get_pwr_pin_name -- invalid pin # - '24' on target BGA package
Problem Description:
Urgency: standard
General Description:
Reference Number: 16224
XIL2CDS may issue the following error:
<output>
ERROR : get_pwr_pin_name -- invalid pin # - '24' Contact
Cadence Customer Support
</output>
Solution 1:
The error message is due to incorrect entries for the BG225
package in the xilinx.pga.pin file. This data files is
located in the 97A directory,
$CDS/share/library/xilinx/data
The workaround is to copy the corrected xilinx.pga.pin file
from the M1.3 release, located in $XILINX/cadence/data, to
$CDS/share/libarary/xilinx/data.
End of Record #2439 - Last Modified: 10/06/97 21:56 |