Answers Database
Foundation F1.x: Bus pin names are not visible on Logiblox components
Record #2602
Product Family: Software
Product Line: Aldec
Product Part: Foundation Project Manager
Product Version: 1.3
Problem Title:
Foundation F1.x: Bus pin names are not visible on Logiblox components
Problem Description:
Urgency: Standard
General Description:
The names of bus pins on Logiblox symbols bus are not shown on
the schematic by default.
Solution 1:
Foundation F1.3
===============
To enable the bus pin names globally, a switch must be added to
the SUSIE.INI file. To edit this file, select File ->
Configuration from the Project Manager, and hit the "View INI
File" button. At the bottom of the file add these lines:
[Logiblox]
show_pinbus_names=yes
This will not affect any Logiblox components already created.
Re-run Logiblox from the Project Manager Tools menu to see the
bus pin names appear on the schematic.
Solution 2:
Foundation F1.4, F1.5
=================
To enable the bus pin names globally, select
File->Configuration from the Project Manager. Place a check
in the box next to "Display LogiBLOX bus pin names."
This will not affect any Logiblox components already created.
Re-run Logiblox from the Project Manager Tools menu to see the
bus pin names appear on the schematic.
End of Record #2602 - Last Modified: 10/06/98 08:22 |