Answers Database


Foundation F1.x: Bus pin names are not visible on Logiblox components


Record #2602

Product Family: Software

Product Line: Aldec

Product Part: Foundation Project Manager

Product Version: 1.3

Problem Title:
Foundation F1.x: Bus pin names are not visible on Logiblox components


Problem Description:
Urgency: Standard

General Description:

The names of bus pins on Logiblox symbols bus are not shown on
the schematic by default.


Solution 1:

Foundation F1.3
===============

To enable the bus pin names globally, a switch must be added to
the SUSIE.INI file. To edit this file, select File ->
Configuration from the Project Manager, and hit the "View INI
File" button. At the bottom of the file add these lines:

[Logiblox]
show_pinbus_names=yes

This will not affect any Logiblox components already created.
Re-run Logiblox from the Project Manager Tools menu to see the
bus pin names appear on the schematic.



Solution 2:

Foundation F1.4, F1.5
=================

To enable the bus pin names globally, select
File->Configuration from the Project Manager. Place a check
in the box next to "Display LogiBLOX bus pin names."

This will not affect any Logiblox components already created.
Re-run Logiblox from the Project Manager Tools menu to see the
bus pin names appear on the schematic.




End of Record #2602 - Last Modified: 10/06/98 08:22

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!