Answers Database
CPLD: What are negative setup times in CPLD Performance report?Record #3302
Product Family: Software Urgency: Standard General Description: After running M1 and creating a 'Post Layout Timing Report', in the timing report (a.k.a. Performance Summary Report), there may be negative values for setup times such as below: Setup to Clock at the Pad (tSU) : -13.0ns (0 macrocell levels) Data signal 'CS10' to TFF D input Pin at '&__A__55.D' Clock pad 'R_W' (Global Clock) Negative setup time is the result of a clock signal that is slower than the total delay and setup on the data input to the ff. Normal (positive) setup time is when the ff data must be stable before clock comes. The equation to calculate the time is: Tsu=Tin+Tlogi+Tsui-Tgck In the case where setup time is negative, the data arrives at the ff, stays for setup, then disappears before the clock comes. In the above equation, Tgck is larger than the sum of the rest, therefore there is a negative Tsu. For more information on this or equations for other configurations, please see the Xilinx App note XAPP071 - Using the XC9500 Timing Model. http://www.xilinx.com/xapp/xapp071.pdf Solution 1: To resolve the timing problem, the data must be maintained on the input of the ff until clock comes (Tgck). The negative Tsu is the additional time the data must remain valid before the clock comes. End of Record #3302 - Last Modified: 01/03/00 13:45 |
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |