 Spartan: Pinouts on the Version 0.6 of the data sheet are incorrect. 
 
 Record #3473
Product Family:  Hardware 
 
Product Line:  Spartan 
 
Product Part:  S20 
 
Problem Title: 
Spartan: Pinouts on the Version 0.6 of the data sheet are incorrect.  
 
 
Problem Description:
  
 
General Description: 
 
The November 25, 1997 (Version 0.6), of the Spartan data sheet 
contains incorrect pinout information. 
 
The package files, however, have been correct all along. 
 
 
Solution 1: 
 
 
The updated data sheet has been available on the Web since 
February 1998, at http://www.xilinx.com/partinfo/db96.htm. 
 
Please refer to Version 1.0 and above. 
 
 
 
 End of Record #3473 - Last Modified: 02/26/98 12:37  |