Answers Database
M1.4: FATAL_ERROR:baslo:basloglobal.c:35:1.9 - on line 972 of file "baslodriver.c"Record #3686
Product Family: Software Optimizer/Partitioner: version M1.4.12 (c) Copyright 1989-1997 Xilinx Inc. All rights reserved. Reading ../xc9500.ngd Considering device XC95144-PQ100. Multi-level logic optimization... Timing optimizationASSERTION FAILED: bool IS NOT TRUE on line 972 of file "baslodriver.c" FATAL_ERROR:baslo:basloglobal.c:35:1.9 - on line 972 of file "baslodriver.c" Process will terminate. Please call Xilinx support. Solution 1: Current workaround: Try increasing the Collapsing Input Limit, this switch is in DM/FlowEngine -> Options -> Edit Templ ate -> Advanced Optimization. Default setting for this in M1.4 is 36 and specifying lower input limit may cause the optimizer impo ssible to fit the design and can result in fatal error. This issue has been resolved in M1.5 End of Record #3686 - Last Modified: 04/08/98 17:22 |
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |