Answers Database


M1.4 Hitop - hitop error: Error:rg119


Record #3732

Product Family: Software

Product Line: CPLD Implementation

Product Part: hitop

Product Version: 1.4

Problem Title:
M1.4 Hitop - hitop error: Error:rg119


Problem Description:
Hitop may fail on designs with lots of heirarchy that have
long signal and instance names. The error is:

   hitop error: Error:rg119




Solution 1:

A fix is available on the Xilinx download area that truncates
signals to 80 characters. A long term fix that requires no
truncation is planned for M2.1 (release after M1.5).

ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_sol10_m14.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_sun10_m14.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_hp10_m14.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_nt10_m14.zipInternet Link

These update files also include the changes from previous cpld updates.

All zip files are created using WinZip. To obtain this utility,
access WinZip's web site at http://www.winzip.comInternet Link





End of Record #3732 - Last Modified: 08/26/98 16:57