MAP: "ERROR:xvkma:120 - LUT* symbol has an equation that has no connected signal" with Synplify 5.0.x


Record #5208

Product Family: Software

Product Line: Synplicity

Product Part: Synplify

Product Version: 5.0

Problem Title:
MAP: "ERROR:xvkma:120 - LUT* symbol has an equation that has no connected signal" with Synplify 5.0.x



Problem Description:
Urgency: Hot

General Description:
When generating implementation netlists for Virtex, selecting
"Result Format: XNF" within Synplify 5.0.x generates following Map error:

ERROR:xvkma:120 - LUT2 symbol "controller.write_sdram_sm.un73_axb_2"
  (output signal=controller.write_sdram_sm.un73_axb_2) has an equation that
  uses an input pin that has no connected signal. Make sure that all the pins
  used in the equation for this LUT have signals that are not trimmed (see trim
  report for details on which signals were trimmed). The original signals
  connected to the LUT are: VCC buffer_max_size[2]
  controller.write_sdram_sm.un73_axb_2.


Solution 1:

This was common in versions of Synplify prior to 5.1.2. If you are using a
more recent version, this error is due to bad connections in the netlist such
as nets that are not driven or hanging. Please contact Synplicity support for
assistance if the below suggestion does not solve your problem.

For versions prior to 5.1.2, select "Result Format: EDIF" when generating
implementation netlists for Virtex. The resultant EDIF now contains
cell declarations for VCC and GND that drive the dangling nets.
Target -> Set Device Options -> Result Format -> EDIF

This is fixed in Synplify 5.1.2 and later. Synplicity has removed the option
of targetting to XNF for Virtex in this version.




End of Record #5208 - Last Modified: 06/26/99 13:49