19 April 1999
Attention: Valued Customer,
Subject: Product Discontinuation Notification (PDN99003).
"Discontinuation of certain members of the XC4000 Commercial and Industrial
Products Line.
Family |
Pkg. |
Obsolete Device |
Replacement Device |
|
|
|
|
XC4003 |
PG120 |
XC4003-6PG120C/I |
XC4003E-4PG120C/I |
|
|
XC4003-5PG120C/I |
XC4003E-3PG120C/I |
|
|
XC4003-4PG120C |
XC4003E-2PG120C |
|
PC84 |
XC4003-5PC84I |
XC4003E-3PC84I |
|
PQ100 |
XC4003-5PQ100I |
XC4003E-3PQ100I |
|
|
|
|
XC4005 |
PQ100 |
XC4005-6PQ100C/I |
XC4005E-4PQ100C/I |
|
|
XC4005-5PQ100C/I |
XC4005E-3PQ100C/I |
|
|
XC4005-4PQ100C |
XC4005E-2PQ100C |
|
PQ208 |
XC4005-6PQ208C/I |
XC4005E-4PQ208C/I |
|
|
XC4005-5PQ208C/I |
XC4005E-3PQ208C/I |
|
|
XC4005-4PQ208C |
XC4005E-2PQ208C |
|
PC84 |
XC4005-5PC84I |
XC4005E-3PC84I |
|
PQ160 |
XC4005-5PQ160I |
XC4005E-3PQ160I |
|
|
|
|
XC4006 |
PG156 |
XC4006-6PG156C/I |
XC4006E-4PG156C/I |
|
|
XC4006-5PG156C/I |
XC4006E-3PG156C/I |
|
|
XC4006-4PG156C |
XC4006E-2PG156C |
|
PC84 |
XC4006-5PC84I |
XC4006E-3PC84I |
|
PQ160 |
XC4006-5PQ160I |
XC4006E-3PQ160I |
|
PQ208 |
XC4006-6PQ208I |
XC4006E-4PQ208I |
|
|
XC4006-5PQ208I |
XC4006E-3PQ208I |
|
|
|
|
XC4008 |
PC84 |
XC4008-6PC84C/I |
XC4008E-4PC84C/I |
|
|
XC4008-5PC84C/I |
XC4008E-3PC84C/I |
|
|
XC4008-4PC84C |
XC4008E-2PC84C |
|
PG191 |
XC4008-6PG191C/I |
XC4008E-4PG191C/I |
|
|
XC4008-5PG191C/I |
XC4008E-3PG191C/I |
|
|
XC4008-4PG191C |
XC4008E-2PG191C |
|
|
|
|
XC4010 |
BG225 |
XC4010-6BG225C/I |
XC4010E-4BG225C/I |
|
|
XC4010-5BG225C/I |
XC4010E-3BG225C/I |
|
|
XC4010-4BG225C |
XC4010E-2BG225C |
|
PC84 |
XC4010-6PC84I |
XC4010E-4PC84I |
|
|
XC4010-5PC84I |
XC4010E-3PC84I |
|
PG191 |
XC4010-5PG191I |
XC4010E-3PG191I |
|
|
|
|
XC4013 |
BG225 |
XC4013-6BG225C/I |
XC4013E-4BG225C/I |
|
|
XC4013-5BG225C/I |
XC4013E-3BG225C/I |
|
|
XC4013-4BG225C |
XC4013E-2BG225C |
|
PG223 |
XC4013-6PG223C/I |
XC4013E-4PG223C/I |
|
|
XC4013-5PG223C/I |
XC4013E-3PG223C/I |
|
|
XC4013-4PG223C |
XC4013E-2PG223C |
|
PQ160 |
XC4013-6PQ160C/I |
XC4013E-4PQ160C/I |
|
|
XC4013-5PQ160C/I |
XC4013E-3PQ160C/I |
|
|
XC4013-4PQ160C |
XC4013E-2PQ160C |
|
PQ208 |
XC4013-6PQ208I |
XC4013E-4PQ208I |
|
PQ240 |
XC4013-6PQ240I |
XC4013E-4PQ240I |
|
|
|
|
XC4025 |
HQ304 |
XC4025-6HQ304C/I |
XC4025E-4HQ304C/I |
|
|
XC4025-5HQ304C/I |
XC4025E-3HQ304C/I |
|
|
XC4025-4HQ304C |
XC4025E-2HQ304C |
|
PG223 |
XC4025-6PG223C/I |
XC4025E-4PG223C/I |
|
|
XC4025-5PG223C/I |
XC4025E-3PG223C/I |
|
|
XC4025-4PG223C |
XC4025E-2PG223C |
|
PG299 |
XC4025-6PG299C/I |
XC4025E-4PG299C/I |
|
|
XC4025-5PG299C/I |
XC4025E-3PG299C/I |
|
|
XC4025-4PG299C |
XC4025E-2PG299C |
|
|
|
|
XC4010D |
BG225 |
XC4010D-6BG225C/I |
XC4010E-4BG225C/I |
|
|
XC4010D-5BG225I |
XC4010E-3BG225I |
|
PC84 |
XC4010D-5PC84I |
XC4010E-3PC84I |
|
PQ160 |
XC4010D-5PQ160I |
XC4010E-3PQ160I |
|
PQ208 |
XC4010D-6PQ208I |
XC4010E-4PQ208I |
|
|
XC4010D-5PQ208I |
XC4010E-3PQ208I |
|
|
|
|
XC4013D |
BG225 |
XC4013D-6BG225C/I |
XC4013E-4BG225C/I |
|
|
XC4013D-5BG225C/I |
XC4013E-3BG225C/I |
|
PQ160 |
XC4013D-6PQ160I |
XC4013E-4PQ160I |
|
|
XC4013D-5PQ160I |
XC4013E-3PQ160I |
|
PQ208 |
XC4013D-6PQ208I |
XC4013E-4PQ208I |
|
PQ240 |
XC4013D-6PQ240I |
XC4013E-4PQ240I |
|
|
XC4013D-5PQ240I |
XC4013E-3PQ240I |
Change Description: Xilinx is discontinuing the above
product/package combinations and providing our customers with a one year
notification to convert to the appropriate XC4000E device. Other XC4000
devices not affected by this PDN are listed in XC4000s
Available after PDN 99003.
Product Change: Since the replacement XC4000E devices
are a subset of the older XC4000 architecture, migrating a design from
the XC4000 to the XC4000E is relatively straightforward. Please refer to
http://www.xilinx.com/apps/4000.htm
(Xilinx app note XAPP062) for more information.
Reason For Change: The above product/package combinations
have declined in customer demand where manufacturing is no longer becoming
economical. In order for Xilinx to continue the evolutionary process of
cost reductions, it is necessary to discontinue these devices. The listed
replacement products (while having faster minimum delays) are form, fit
and functionally equivalent to the discontinued parts (meeting all specifications
in the appropriate data sheets).
Key Dates:
Final orders accepted until 15 April, 2000
Final deliveries on or before 15 June, 2000
Response: No response to this notification is required.
Requests for additional data or support should be made within 90 days of
notification. Please address any questions you may have via e-mail at "pcn@xilinx.com",
or directly by fax at 408 559 1368.
Sincerely,
Joseph J. Fabula
Director Q/A |