All, When using any of the spice primitives defined in Annex E, should these be able to handle the hierarchical system parameters ($mfactor, $xposition, etc.) given that they are automatically added to every module? Linear components can be easily handled, but things are definitely different for more complex built-in components such as MOSFETs and BJTs which often have their own handling of the multiplicity factor, for instance for noise calculations. Should the connection between $mfactor and the models own multiplicity factor be made by the user or should it be handled automatically, i.e. similar to the handling of a Verilog-A implementation of the same model. Should it be possible to use aliasparam for the hierarchical system parameters, for instance to map $mfactor to a model that already has a similar parameter? As an example, the Verilog-A code of the PSP model already contains the MULT parameter which is equivalent to $mfactor. Regards, Marq Marq Kole Competence Leader Analog Simulation, Philips ED&TReceived on Thu Apr 27 04:50:01 2006
This archive was generated by hypermail 2.1.8 : Thu Apr 27 2006 - 04:50:17 PDT