Re: Fw: more Clause 3 comments

From: Jonathan David <j.david_at_.....>
Date: Thu Jun 05 2008 - 14:53:49 PDT
hm.. the I normally use an ams simulator, so I have to wait until after the analog engine initializes to see anything.. 
jbd

 Jonathan David
j.david@ieee.org
jb_david@yahoo.com
http://ieee-jbdavid.blogspot.com
Mobile 408 390 2425


----- Original Message ----
From: David Miller <David.L.Miller@freescale.com>
To: Verilog-AMS Reflector <verilog-ams@eda.org>
Sent: Thursday, June 5, 2008 2:27:36 PM
Subject: Re: Fw: more Clause 3 comments

Ok, if I probe the value of the wire after 1 tick then both simulators agree 
with the uninitialized wire set to 'z'.

It is just strobing the value before any steps are taken that show some 
discrepancies.
Perhaps using display tasks to show default values is not the best way to go.
Thanks for the response David, I understand now how undriven nets default to 
'z', as opposed to nets with drivers that default to 'x'.

Cheers...
Dave


Jonathan David wrote:
> the list was in the cc list .. 
> forgot to reply to all
> 
>  Jonathan David
> j.david@ieee.org
> jb_david@yahoo.com
> http://ieee-jbdavid.blogspot.com
> Mobile 408 390 2425
> 
> 
> ----- Forwarded Message ----
> From: Jonathan David <jb_david@yahoo.com>
> To: David Miller <David.L.Miller@freescale.com>; Nourdine Belhous <nourdine_belhous@mentor.com>
> Cc: Verilog-AMS LRM Committee <verilog-ams@eda.org>
> Sent: Thursday, June 5, 2008 12:19:57 PM
> Subject: Re: more Clause 3 comments
> 
> the one I use every day (the product of a former employer of mine) 
> leaves the wire to z but the reg to x .. 
> makes sense to me.. if the net has no drivers - the value is undriven (z)
> if the net has a driver (ie a reg) but its value is not known.. its value should be unk (ie x)
> 1. we should carefully look at what 1364-2005 has to say about this.. and check to see if the simulator
> that is NOT following the standard as written has a switch to enable the conforming option.. 
> (or if your environment setup in the other one has some pli or something that turns all z to x.. - or a command line option)
> 
> See 1364-2005 4.2.1
> the one that has the net at X is NOT conforming to the (latest) verilog standard.. 
> at least as setup on your site.. 
> jbd
> 
> 
> 
> 
> Jonathan David
> j.david@ieee.org
> jb_david@yahoo.com
> http://ieee-jbdavid.blogspot.com
> Mobile 408 390 2425
> 
> 
> ----- Original Message ----
> From: David Miller <David.L.Miller@freescale.com>
> To: Nourdine Belhous <nourdine_belhous@mentor.com>
> Cc: Verilog-AMS LRM Committee <verilog-ams@eda.org>
> Sent: Wednesday, June 4, 2008 9:28:40 AM
> Subject: Re: more Clause 3 comments
> 
> Hi Nourdine,
> Thanks, I changed my example to be 'wire mywire' instead.
> Unfortunately, when I tried this with two different commercial digital 
> simulators, one gives
>    mywire = x
> 
> the other
>    mywire = z
> 
> So even the pure digital simulators don't seem to agree.
> 
> Cheers...
> Dave
> 
> 
> Nourdine Belhous wrote:
>> Hi,
>> If you want to test the initial value of a net, you should declare a 
>> wire (or anything specified as a net in the digital LRM) instead of a 
>> register.
>> And you'll probably get a value of 'z' from the simulator.
>>
>> Nourdine BELHOUS.
>>
>> David Miller wrote:
>>>> 3.7: "Unlike other digital nets which have an initial value of ‘x’,..."
>>>> Digitial nets have an initial value of z, not x.
>>>>
>>> I am confused.
>>> If I have:
>>>
>>> module test;
>>> reg myreg;
>>> initial $display("myreg = %b",myreg);
>>> endmodule
>>>
>>> Digital simulators print:
>>>   myreg = x
>>>
>>> How is this value different from the initial value of myreg?
>>>
>>>
>>> Dave
>>>
>>>
>>>
>>
> 

-- 
==============================================
-- its another day for you and me in paradise
--
-- David Miller
-- Design Technology (Austin)
-- Freescale Semiconductor
-- Ph : 512 996-7377 Fax: x7755
==============================================

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Thu Jun 5 15:11:38 2008