Answers Database
MODELSIM VLOG: ERROR: ../../../<design>.v: Port 'OUT' not found in module
Record #6535
Product Family: Software
Product Line: Merged Core
Product Part: simprims
Problem Title:
MODELSIM VLOG: ERROR: ../../../<design>.v: Port 'OUT' not found in module
Problem Description:
Urgency: Standard
When doing a functional simulation of a Logiblox generated
Verilog module, the following error messages are generated:
ERROR: ../../../<design>.v: Port 'OUT' not found in module
ERROR: ../../../<design>.v: Port 'IN1' not found in module
Solution 1:
This is most likely a result of using incompatible simulation libraries with the
LogiBlox module. Specifically, if the Logiblox module was created by version
1.5i (or earlier) of the Alliance or Foundation software, and the designer is
simulating with 2.1i (or later) version of the SIMPRIMS libraries.
The reason is that the port names have been changed from the previous
versions of the software. By re-creating the module using Logiblox 2.1i will
resolve this problem. See (Xilinx Solution 4258) for more details.
End of Record #6535 - Last Modified: 10/27/99 10:10 |