In many situations it is better to implement a digital filter
in terms of first- and/or second-order elementary sections,
either in series or in parallel. Such an implementation
may have numerical advantages as well. In the time-varying case, it
is easier to control fundamental parameters of small sections, such as
pole frequencies, by means of coefficient variations.