Re: Merged version of chapter 6

From: Geoffrey.Coram <Geoffrey.Coram_at_.....>
Date: Fri Jun 16 2006 - 06:19:49 PDT
I guess there are two possibilities that might have been implemented:
1) other values disable the cross
2) any positive value is interpreted as +1, any negative as -1

Ken says that Cadence uses (1).  Are there any simulators that do (2)?

The sentence I copied from the LRM seems to indicate that it would be
an error to use a value other than 0,+1,-1 (though the LRM doesn't
quite use IEEE-standard language (shall)).

-Geoffrey



Sri Chandra wrote:
> event. I am not sure how many implementations interpret it in that
> fashion ie. arguments not +1, 0, -1 disable the cross, and this is going
> to lead to compatibility issues with existing implementations.
>
Received on Fri Jun 16 06:19:51 2006

This archive was generated by hypermail 2.1.8 : Fri Jun 16 2006 - 06:19:53 PDT