Re: disallow distributed switch branches

From: Geoffrey.Coram <Geoffrey.Coram_at_.....>
Date: Wed Apr 18 2007 - 11:31:17 PDT
Kevin Cameron wrote:
> 
> I see absolutely no reason for disallowing these cases. As previously
> discussed, the behavior of an analog statements should not change if
> they are moved from separate modules into the same module

Much as you'd like this to be true, we discussed this in last
week's call and decided it doesn't work when contributing to
potentials.  Since named branches are declared at module scope,
if you contribute to the potential of a branch in two analog
blocks, the values add; if you put the analog contrib statements
into separate modules, the potentials are in parallel (and you'll
get an error from many simulators).

-Geoffrey

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Wed Apr 18 11:31:33 2007